Electric
Supply voltage:
534178 (WT82BL208)
534179 (WT82BR208)
534180 (WT82BL240)
534181 (WT82BR240)
Dishwasher requires two separate electrical service connections.
Connection 1 for RINSE MODULE; Connection 2 for WASH MODULE.
Refer to below table for Amp requirements.
Connection 1:
208 V/3ph/60Hz
240 V/3ph/60Hz
Connection 2:
208 V/3ph/60Hz
240V/3ph/60Hz
Total Amp Load:
208 V/3ph/60Hz
240 V/3ph/60Hz
Exhaust Requirements
Unit supplied as standard with extended vent hoods
(can be removed during installation if not required).
Exhaust extraction not more than 177 CFM (300m³/h)
Refer to installation diagram for minimum exhaust hood
installation height .
Key Information
Productivity racks per hour
(max speed):
Productivity racks per hour
(min speed):
Table to Table connection:
Number of Tanks:
Height with door open:
Charging hole size (width):
Charging hole size (height):
Shipping weight:
Shipping width:
Shipping depth:
Shipping height:
Shipping volume:
Noise level:
Unit predisposed to accept external detergent dispensers, detergent
probes and rinse aid dispensers.
Warewashing
82" " " " " Multi Tank Conveyor Dishwasher WT82
208 V/3ph/60Hz
208 V/3ph/60Hz
240 V/3ph/60Hz
240 V/3ph/60Hz
71A
62A
69A
62A
133.8A (44.1kW)
118.9A (44.1kW)
350 racks / 6300 dishes
(average 18 dishes per rack)
250 racks / 4500 dishes
(average 18 dishes per rack)
82-5/8" (2098 mm)
2
83-7/16" (2119 mm)
20-7/8" (530 mm)
19-3/4" (501 mm)
1268 lb (575 kg)
93-5/16" (2370 mm)
40-15/16" (1040 mm)
81-1/8" (2060 mm)
157 cu.ft (4.46 m³)
<70 dBA
82" Multi Tank Conveyor Dishwasher
Water
Inlet Water Supply Pressure:
Inlet Hot Water Supply Temperature
for wash and rinse section:
Inlet Water Supply Hardness:
Incoming Hot Water Line Size
(wash and rinse section):
Drain line size (wash section):
Drain line size (rinse section):
Hot Water consumption: Gallons/hr:
Water consumption/rack:
Wash Temperature:
Wash tank size:
Wash pump power (top wash arms):
Wash pump power (lower wash arms): 1.5 hp (1.2 kW)
Power Rinse Temperature:
Power rinse tank size:
Rinse pump power:
Final Rinse Temperature:
Final Rinse water flow:
Hot water booster capacity:
Initial fill Hot Water requirements:
Warewashing
WT82
22 – 102 psi (150 – 700 kPa)
140 °F (60 °C)
4-8 gpg (7-14 °fH) max
G 3/4"
G 1-1/2"
G 1-1/2"
87 gal/hr (330 liters/hr)
0.3 gal/rack (0.75 l/rack)
160 – 172 °F (71-78 °C)
40 gal (150 liters)
3 hp (2.2 kW)
160 – 172 °F (71-78 °C)
6 gal (23 liters)
0.4 hp (0.32 kW)
180 – 194 °F (82-90 °C)
79 gal/hr (300 l/hr)
3.17 gal (12 liters)
40 gal (150 liters)