Note: Please make the waterer front level is a little higher than back level for
easier drain, and please also make sure that tilt would not more than 5 degrees.
Otherwise will cause the seal plunge not seal well.
3. Then screws the steel plunge into the end of the chain. When the motor is
released fully, the plunge should be well pressured to the bottom seal. Fig 4
Fig 4
4. Install the float. Unscrew nut on the float, put the thread of the float throught the
hole of the water spenser, then srew the nut back again to the float thread which
will hold the float to the body of the waterer. User can adjust angle of the float
through the adjusting button, so to adjust water level of water dispenser. Suggestion
put float flat. Fig5
2