ATI Audio DDA416 Manuel d'utilisation et d'entretien - Page 8

Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation et d'entretien pour {nom_de_la_catégorie} ATI Audio DDA416. ATI Audio DDA416 14 pages. Quad 1x4 aes/ebu distribution amplifier and 1x6 clock distribution amplifier

ATI Audio DDA416 Manuel d'utilisation et d'entretien
AES/EBU Input 2
Provides a balanced, transformer isolated 110 ohm AES/EBU input that may be routed to Outputs
1 – 4, 5 – 8, 9 – 12 and/or 13 – 16 via the configuration DIP switches. This input may also be
routed to the six BNC outputs.
 
AES/EBU Input 3
Provides a balanced, transformer isolated 110 ohm AES/EBU input that may be routed to Outputs
1 – 4, 5 – 8, 9 – 12 and/or 13 – 16 via the configuration DIP switches. This input may also be
routed to the six BNC outputs.
 
AES/EBU Input 4
Provides a balanced, transformer isolated 110 ohm AES/EBU input that may be routed to Outputs
1 – 4, 5 – 8, 9 – 12 and/or 13 – 16 via the configuration DIP switches. This input may also be
routed to the six BNC outputs.
 
AES External Sync In
Provides a balanced, transformer isolated 110 ohm AES External Sync input that may be routed to
Outputs 1 – 4, 5 – 8, 9 – 12 and/or 13 – 16 via the configuration DIP switches as a Word Clock.
This input may also be routed to the six BNC outputs.
 
AES Loop-Thru
Provides a convenient loop-thru port for the AES External Sync input. When looping this signal to
another device, set Input Termination to Off.
 
Word Clock Input
Provides an isolated Hi Impedance or 75 ohm Word Clock input to drive the six BNC Clock Outputs
via the configuration DIP switches. This input may also be routed to AES/EBU Outputs 1 – 4, 5 – 8,
9 – 12 and/or 13 – 16 as a Word Clock.
 
Word Clock Loop-Thru
Provides a convenient loop-thru port for the Word Clock input. When looping this signal to another
device, set Input Termination to Off.
 
DDA-­‐416/WC106   M anual  
8