Forms+Surfaces HELIO BOLLARD Instructions d'installation et de câblage - Page 3

Parcourez en ligne ou téléchargez le pdf Instructions d'installation et de câblage pour {nom_de_la_catégorie} Forms+Surfaces HELIO BOLLARD. Forms+Surfaces HELIO BOLLARD 4 pages.

HELIO
BOLLARD
STEP BY STEP
FOR ALL SURFACE MOUNT HELIO BOLLARDS
7
11-13mm
(0.47in.)
Locate and prepare wires
Note: Installation should be performed only
by qualified individuals.
• Before proceeding with wiring of luminary,
check to ensure that all applicable site
wiring and safety codes have been
followed.
• Locate wires at base of light fixture.
• Ensure power supply is shut off and circuit
being used is isolated.
• Prepare wiring from site junction box and
bollard by stripping and removing
11-13mm (.47") of insulation.
Note: Wire used should be 22-14 AWG
copper conductors.
Caution: Installation of a surge protector as
part of each unit's wiring is recommended.
T 800.451.0410 | www.forms-surfaces.com
© 2021 Forms+Surfaces® | All dimensions are nominal. Specifications and pricing subject to change without notice. For the most current version of this document, please refer to our website at www.forms-surfaces.com.
SURFACE MOUNT WITH J-BOLTS INSTALLATION & WIRING INSTRUCTIONS
8
Connect wires
• Insert ground (green), neutral (white), and
positive (black) wires into provided wire
nuts, being sure to match wire color
codes from junction box to bollard.
• Tighten wire nuts until exposed wire ends
are below bottom of wire nut.
• Inspect all wiring and connections before.
Caution: Light fixture rated for 120-277
VAC power.
9
Place bollard
• Slide bollard over base plate, lower and
align mounting holes.
page 3 of 4 | Rev. 05-25-21