KEY PROGRAMMING PROCEDURE
If required, use the following procedures to program a new set of Smart Key
and/or Bypass Transponder Cards. Both set of Smart Keys or the Bypass
Transponder Cards must be present and accessible during programming.
Enter Programming Mode
Disarm the system by a valid Smart Key or Bypass Transponder Card. Turn the
Ignition Key to the ACC position. After few seconds switch the Ignition Key to
OFF position and immediately back to ACC position for five times or as following:
OFF ACC OFF ACC OFF ACC OFF ACC OFF ACC. Keep the Ignition
Key in ACC position at the fifth time and the horn will sound twice. (Turn the
Ignition Key to OFF position at any time will exit the programming mode with horn
sound three times)
Smart Key(s) Programming
1. After enter the Smart Key programming mode, LED indicator turns RED. You have
30 seconds window to program. If you do not wish to program Smart Keys, press
the brake pedal once to skip to Bypass Transponder Cards programming (Horn
will sound once to confirm)
2. Press and hold the LOCK button on the first Smart Key until horn sound once.
3. Press and hold the LOCK button on the second Smart Key until horn sound once.
4. Smart Keys programming is now completed. System will automatically enter
Bypass Transponder Cards programming mode.
Bypass Transponder Cards Programming
1. After enter the Bypass Transponder Card programming mode, LED indicator
turns BLUE. You have 12 seconds window to program. To skip Bypass
Transponder Cards programming, press the brake pedal once will end the
programming mode with horn sound five(5) times.
2. Hold first Bypass Transponder Card against the reading field of the Backup
Antenna until the horn sound once.
3. Repeat for the second Bypass Transponder Card until the horn sound five(5)
times to indicate key programming has been successfully completed.
Note: Only one Bypass Transponder Card should be sensed in the reading field
at a time. The sensing range for the Bypass Antenna is under an inch.
Horn Sound Summary Table
Number of Horn Sound
10
© Copyright Advanced Keys Inc. 2011. All Rights Reserved.
1 x
2 x
3 x
5 x
Mode Description
Remote / Key Registered
Entered Programming mode
Programming failed
Programming successful