Anden A210V1 Manuel d'installation et d'utilisation - Page 11

Parcourez en ligne ou téléchargez le pdf Manuel d'installation et d'utilisation pour {nom_de_la_catégorie} Anden A210V1. Anden A210V1 16 pages.
Également pour Anden A210V1 : Manuel de démarrage rapide (4 pages), Manuel de démarrage rapide (2 pages)

Anden A210V1 Manuel d'installation et d'utilisation

ALTERNATIVE EXTERNAL CONTROL

Alternatively, use any other humidity control system as long as it has a dry contact, normally open output dedicated to controlling the dehumidifier�
Reference the installation literature provided with the alternative control for wiring, set-up, and operating details�
TO INSTALL AND USE AN ALTERNATIVE EXTERNAL CONTROL,
COMPLETE ALL STEPS:
1. Unplug the dehumidifier or turn off power to the circuit at the
breaker or fuse�
2. Run thermostat cable (use 18-22 AWG wire) from the alternative
external control to the control of the dehumidifier�
3. Trim about 1/4" of insulation from the end of the wires on each
end� Insert the wire into the terminals as shown in FIGURE 11�
4. Restore dehumidifier power�
FIGURE 11 – ALTERNATIVE EXTERNAL CONTROL WIRING
EXTERNAL
CONTROL
TO SET THE DEHUMIDIFIER TO USE THE ALTERNATIVE CONTROL,
COMPLETE ALL STEPS:
1. With power to the dehumidifier, use the ON/OFF button to set the
dehumidifier to the OFF position�
NOTE: If the display backlight is not on, the first button press (any
button) will only turn the backlight on� Press the button a second
time to achieve the desired function�
2. Hold the MODE button on the on-board control for 3 seconds to
enter the Installer Set-up Menu�
3. Press MODE again and the display should change to EXTERNAL in
the center, and DISABLED on the right� Use the UP or DOWN arrow
buttons to set this to ENABLED�
4. Once the display reads EXTERNAL ENABLED, press the MODE
button to cycle through the other settings until the display blinks
DONE for 3 seconds�
5. Use the ON/OFF button to turn the dehumidifier ON� The display
on your unit should read EXTERNAL� Even if there is a demand for
90-2542
dehumidification according to your external control, the dehumidifier
will wait 3 minutes before turning on for the first time only�
90-1854
English 11