Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation et d'entretien pour {nom_de_la_catégorie} Electrolux AOFP101U4. Electrolux AOFP101U4 27 pages. Bcf 30kg 6 gn1/1 lw (240/3/60hz), bcf 50kg 10 gn1/1 lw (240/3/60hz) / bcf 100kg 20 gn1/1 lw (240/3/60hz) / bcf 70kg 10 gn2/1 lw (240/3/60hz) / bcf 180kg 20 gn2/1 lw (240/3/60hz) / bcf 30kg 6 gn1/1 lw (208/3/60hz) / bcf 50kg 10 gn1/1 lw (208/3/60hz) / bcf

Electrolux AOFP101U4 Manuel d'utilisation et d'entretien

C.1.8 TIME

• During a chilling cycle: the time display shows the total or
remaining chilling time.
• During holding cycle: the display shows the hour.
• During "turbo cooling" cycle: the display shows:
°°°°
"
" = two hours left until start of defrosting
°°°
"
" = 1.5 hours left until start of defrosting
°°
"
" = 1 hour left until start of defrosting
°
"
" = 0.5 hours left until start of defrosting
The TIMED CYCLE INDICATOR LIGHT
when a timed blast chilling cycle is running.
During the cycle selection phase it indicates the chilling time.
The "estimated remaining time" LED
as the electronic card calculates the time remaining until the
end of cooking with shaft probe. Once it has been measured,
the time is shown on the time display.

C.1.9 UTILITIES

When the
button is pressed it lights up behind. Use the
buttons to scroll backwards and forwards and select
the utility. Press
After entering the "Utilities" menu, the system will go back to the
main menu if no button is pressed for 5 seconds.
See below for a DESCRIPTION OF THE UTILITIES FUNCTIONS.
lights up only
comes on as soon
to confirm.
C.1.9.1 MANUAL DEFROSTING
If the appliance is in the right conditions (indicator light
or
or with the appliance on stand-by), this function
enables a manual defrosting cycle. The display shows the
message "dEfr" throughout the entire cycle.
If a manual defrosting is not possible (during a chilling cycle) the
message " UTIL NONE" will appear on the display.
The selection is enabled only in preservation/maintenance and
when selecting the operating cycle.
When the defrosting is finished the system will go back to the
main configuration.
C.1.9.2 PROBE TEMPERATURES DISPLAY
This function displays the probe temperatures, if there is more
than one probe inserted in the product.
If just one probe is used, see section C.1.5 for instructions on
how to display the temperature.
C.1.9.3 "UV"STERILIZATION CYCLE
(Function for appliances with germicidal light option)
The UV lamps have a direct germicidal action and are used to
sterilize the surfaces and air in the chamber of the appliance
(see section B.1.4)
To active "UV", no cycles must be running. When the cycle is
running the "TEMPERATURE" display shows the chamber
temperature. When the cycle is finished the system goes back
to the main menu.
If a sterilization cycle is not possible because of the status of the
appliance, the message "UTIL NONE" will appear on the display.
13