SSA80 series burners consists of combustor, nozzle, orifice plates and rear cover, different
components are connected together with bolts to form the Burner. Shown as below Fig 1
is exploded drawing view, in which the burner body and rear cover are made of cast iron,
nozzle, combustor and orifice plates are stainless steel, and the combustor could be
refractory or SiC tube in high temperature application.
7. Burner Operation Data
Following table 1 shows the SSA80 series burner operation data. (unit: mm), below data
based on Natural gas, high velocity combustor and atmosphere air.
NG Inlet
Input
Type
kW
80G130
13-130
80G200
22-200
80G270
27-270
80G400
40-400
80G530
53-530
80G800
80-800
80G1300
130-1300
80G2000
200-2000
80G2700
270-2700
*
400-4000
80G4000
*
600-6000
80G5300
Notes:
*Orifice plate is rectangle shape.
– The above data is based on net heat value (LHV).
– Normal condition: 1 atmosphere, 0°C.
– Actual data varies by each application condition.
– Pressure or pressure difference value is based on 20 °C, excess air 15%.
– Orifice diameter based on Natural gas as fuel.
– Flame length is measured from the combustor outlet, fuel is natural gas, running on
ratio.
Anderson Thermal Soluions(Suzhou)Co., Ltd
Table 1: SSA80 series of burner operation data.
NG
Air Inlet P
P
(mbar)
DP (mbar)
(mbar)
Max
Max
Max
40
41.5
13.0
34.5
40
13.0
31
41
8.5
36
44
11.5
23
31
11.5
31
38
11.5
34
46
9.0
34
42
11
35
42
9.5
40
49
14.0
35
52.5
15.0
Anderson Thermal Solutions – SSA80 Operation Manual
Orifice Diameter
CA DP
(mbar)
Min Max
Min
NG
0.2
13.5 0.2
11.5
0.2
15.0 0.2
13.5
0.2
15.0 0.2
18.0
0.2
16.0 0.2
20
0.2
18.0 0.2
24.0
0.2
18.5 0.2
29.0
0.2
13.5 0.2
37.0
0.2
13
0.2
45
0.2
9.5
0.2
52.0
10.0 0.2
0.2
60.0
11.5 0.2
0.2
65.0
4
Max CA
mm
Temp
(°C)
Air
42.0
450
49.0
450
57.0
450
66.0
450
70.0
450
90.0
450
125.0
450
150
450
155.0
450
222.3x152.3
450
232.3x162.3
450
Flame
Length
(mm)
635
710
835
965
864
1270
1900
2540
3150
2750
2134