10.7 Prepare for adjustment

After the installation of the burner system components is complete, the following steps
should be followed in order to prepare for adjustment:
– Set the air flow switch so that it drops out at 50% of the maximum pressure of the
combustion air blower.
– Set the low gas pressure switch at 50% below the gas pressure measured at the inlet
to the main gas valve train.
– Set the high gas pressure switch at 50% above the gas pressure measured at the
inlet to the main gas valve train.
– Try to ignite the burner before the purge and other timers have finished their cycles.
Make sure that the flame monitoring system indicates a flame failure.
– Trip out the pressure switches and other limit interlocks. Make sure that the main
gas valve train closes.
– If the simulated limit condition or the simulated flame fault cannot be responded at
the specified fault response time, the fuel system needs to be turned off to correct
the existing problems.

10.8 Burner commission

Special attention:
The ANX70 Series burners, described herein, are designed to mix fuel with air. All fuel
burning devices will cause fires and explosions if improperly applied, installed, adjusted,
controlled, or maintained. Do not bypass any safety feature, never try to light a burner
if it shows signs of damage or malfunction.
If adjusting the burner for the first time, must follow these steps:
1.
Reset the system: Start combustion blower with valve fully open, close all the
automatic gas valves and manual gas cocks. Pay more attention to rotate direction
of blower.
2.
Set the system to high fire, but DO NOT ignite the burner(s). Use the datasheet
from the appropriate ANX70 burner table to set the differential air pressure
needed at high fire.
3.
Set the system to low fire air. Drive to low fire position. Measure pressure with
manometer set to 0.5 mbar. This is the initial setting only. Further adjustment may
be required.
4.
Make sure all the settings are still the same after you cycle the system several times
between high and low fire.
5.
Burner ignition: open all the manual shut off valves, make sure air blower is
running, automatic control valve is driven to low fire by flame controller, start
spark ignition, gas safety shut off valves open and flame on, flame signal feedback
to controller, adjust gas and combustion pressure by the opening gas/air control
valve till strong flame signal achieved.