Andi-Co Australia Pty Ltd
Fan blower
Loose screws
Fan motor noise.
Worn bearings
Voltage
Wiring
Compressor will not
Main PCB failure
run while fan motor
Capacitor (Discharge
runs.
capacitor before testing)
Room temp sensor
Compressor
Excessive noise.
Copper tubing
Water tank full
Water depth sensor if failure
Water pump failure
Water full alarm
Water depth is over load in
chassis
Water depth sensing
structure
Cooling or heating
Air filter
feels not good
Air discharge pipe
Unit undersized
Condenser and Evaporator
Water shower failure
Fan motor
Air flow
Less refrigerant
Capillary tube
Replace the fan blower if cracked, out of balance, or partially
missing.
Tighten them.
Replace the motor if knocking sounds continue when running or
loose, or the motor hums or noise appears to be internal while
running.
Check voltage. Call Supply Authority if not within limits.
Check the wire connections, if loose, repair or replace the
terminal. If wires are off, refer to wiring diagram for identification,
and replace. Check wire locations. If not per wiring diagram,
correct.
Check voltage of main PCB. Replace the main PCB if open.
Check the capacitor.
Replace if not within +/-10% of manufacturers rating. Replace if
shorted, open, or damaged.
Check the temperature setting if not at the coolest (in cooling
mode) or the warmest (in heating mode). Set it if not.
Check the compressor for open circuit or ground. If open or
grounded, replace the compressor.
Remove the cabinet and carefully rearrange tubing not to contact
cabinet, compressor, shroud and barrier.
Check and pour if the water tank is full.
Check and replace if failure.
Check and replace if the pump if failure.
Check and drainage the water in the chassis by open the drainage
hose on the chassis.
Check and replace or realign if the structure is failure.
Clean or replace if restricted.
Realign and assemble if the installation of the air discharging pipe
failure. Replace if damaged.
Determine if the unit is properly sized for the area to be cooled or
heated.
Clean or replace if restricted.
Check the structure of water showering system and clean if
blocked.
Check the fan capacitor and replace if not within +/-10% of
manufactures rating.
Clean or remove if any barrier is found to block the inlet/outlet
wind flow of the unit.
Check the tubes for reasons of leakage. Recycle the refrigerant,
correct the leakage points and recharge.
Regulate the flow if capillary tube and make the evaporating
temperature appropriate if the evaporator is frosted. Replace if
blocked. Repair joint if leaking.