4.
IDENTIFICATION
You can connect:
CNTR 1: One dry-contact fast meter input (max 1 kHz): "Counter 1" or 1 digital input
WIRECUT: 1 dry-contact for to monitor disconnection/cut wire. This input is monitored
once/min.
CNTR 2: 1 dry-contact slow meter input (max 10 Hz): "Counter 2" or 1 digital input
GND: Ground
The sensor ID is visible on the exterior product label and next to the batteries inside the device.
ACW-MR2_QIG_FR_V2.5
The battery polarity is indicated on the circuit
board. The + pole points toward the terminal block
and the – pole toward the antenna. The insulation
tab must be pulled out from one of the battery
terminals before you first use the device.
If a second battery is added, it must be added in
parallel, in the same direction as the first battery.
Start-up phases:
From 0 to 3 sec: bootloader.
From 3 sec to 8 sec: configuration
From 8 sec to 10 sec: configuration is applied, green
LED flashes, red LED flashes if Wirecut is detected.
After 15 sec: switches to stand-by
From 1 min to 5 min: keep-alive frame sent out for
the 1
The keep-alive frame is then transmitted every 4
days.
- Complete technical manual available at www.atim.com -
st
minute, then a message frame every minute.