In mirror mode, the radio frame is
secured with addressing (last octet
of the serial number) and with an
error controller. By default the
ARM-IO is configured in slave mirror
mode.
After
configuration
switch
on,
the
modems
automatically pair each other.
2.3. Frequency table
Channel
1
3
5
7
9
D (13)
F (15)
3. Technical characteristics
ARM-IOD-LP
Interface
Logical input
Delay
Operating modes
Configuration
Power supply
Max consumption
Frequency radio
Radio
Range
Connection
Box
Functioning/storage
temperature
Conformity
4. CONFIGURATION IN MODBUS MODE
The modem configuration can be made in the manufactory.
For erasing the modem configuration:
– Disconnect the battery
– Run down the remaining voltage in shorting circuit the + and the - of the battery connector
The modbus mode is frequently used with a master
modbus automaton or with a supervisor connected to an
ARM-IOS or an ARM-SE.
The sensor mode works with master ARM-SE radio
modem, which can repatriate automatically and cyclically
the information (datalogging). Data are then searchable
in mdbus.
Vous pouvez utiliser les ARM-IO avec les autres modems
and
de la gamme ARM : ARM-SE, ARM-D, ARM-DA, ARM-X,
will
etc.
Frequency (MHz)
868,075
868,175
868,275
868,375
868,475
869,475
869,575
2 digital inputs
Negative logical
Max frequency counting: 100Hz
"Wake-up" delay : 1,55
Answer delay : 3,55
Modes : mirror, Modbus, sensor
Automatic
3,6V battery withdrawable
25mA (Rx) – 60mA to 25mW (Tx) – 15µA in sleep mode
868,000 à 869,900MHz – Puissance max 25mW
Modulation FSK – Debit : 9600
As far as 1km en outdoor
6 points bloc connector (screw thread : 2,54mm)
ABS (IP65) : 65x60x40mm (without antenna)
-20°C to +55°C / -40°C to +70°C
ETS300-220-3 v1.1.1 / EN 301 489-3 v1.4.1
Notice technique complète sur
Default powerful
25mW
25mW
Characteristics
www.atim.com
FRQIG_ARM-IOD-LP
Page3/4
ARM-IO
are
performing sleep mode (configuration
only with modbus commands. See the
use manual).
Duty cycle
Range
1%
<1km
10%
<1km
provided
with
a