T RO u B lE s hO O T IN G
ProBlEM
inDicaTor
no water
1.Sensor flashes
coming out
continuously when
of the mixer
user's hands are within
or tap:
the sensor's range.
2. Red light in the sensor
does not flash once
when user's hands are
within the sensor's
range.
3. Red light in the sensor
flashes once when
user's hands are within
the sensor's range.
water flow
1. Sensor flashes once
from spout
when user's hands are
does not
within the sensor's range.
stop:
2. Red light in the
sensor does not flash
once when user's hands
are within the sensor's
range.
water flow
diminished
* "Security Mode": If the sensor is covered for more than 90 sec. the mixer or tap will automatically shut off
water flow. to return to normal operation remove any blockage.
** In this case, the water flow will stop anyway after 90 seconds because of the security time.
cauSE
Low battery.
1. Range is too short.
2. Range is too long.
3. Battery is completely used up
4. Unit is in "Security Mode"*
5. Sensor is picking up reflections from
the washbasin or another object.
1. connectors between the electronic
unit and solenoid are disconnected.
2. debris or scale in solenoid.
3. the central orifice in the diaphragm
is plugged or the diaphragm is torn
4. the water supply pressure is higher
than 800kPa.
5. the water supply pressure is under
800kPa and yet the pressure in the
mixer or tap's body is higher. this
situation could be caused by a sudden
increase in the water supply pressure
that the check valve prevents from
dropping, even after water supply
pressure drops under 800kPa.
debris or scale in diaphragm
1. Sensor is dirty or covered.**
2. Sensor is picking up reflections from
the washbasin or another object.
Filter or aerator is clogged
SoluTion
Replace battery.
Increase the range.
decrease the range.
the battery must be replaced.
Eliminate cause of reflection.
connect the electronic unit
connectors to the solenoid.
Unscrew solenoid, pull out the
plunger and the spring from the
solenoid and clean them. Use
scale remover material if needed.
when replacing the plunger,
please make sure that the spring
is in vertical position.
clean the orifice or replace
diaphragm.
Reduce the supply water
pressure.
Shut off water supply and
unscrew one of the flexible pipes
in order to reduce the pressure
that blocks the product.
clean the orifice or replace
diaphragm.
clean or eliminate case of
interference.
1. decrease the range or
eliminate cause of reflection.
Remove, clean, re-install
15