PLUMBERS ADJUSTMENT INSTRUCTIONS
Adjusting the TEMPERATURE LIMITING STOP (Fig.2)
The cartridge fitted in this mixer has been factory pre-set to deliver
the maximum available hot water temperature. To use the Temperature
Limit feature adjust the cartridge as follows:-
Carefully remove plug (1) before using a 2.5mm allen key (2) to loosen
grub screw (3) and remove handle (4). (See details on side 1 of this sheet.)
To remove the Hot Limit Stop segment (7) from the cartridge (9), use a flat
bladed screwdriver and carefully lever the segment in an upwards direction.
Rotate the segment (7) in a clockwise direction to reduce the maximum hot
water temperature then refit the segment (7) onto the cartridge (9).
Note:- Start by rotating the segment (7) in small increments, then check the
hot water temperature with the mixer handle in the fully open maximum
hot water position. The segment (7) can be removed & repositioned until the
desired maximum hot water temperature is achieved.
Ensure the segment (7) is pushed fully down onto the cartridge (9). Locate
and hold the handle (4) onto the cartridge (9), then tighten grub screw (3).
Replace plug (1), taking care that the red indication is to the left.
Adjusting the WATER SAVING SCREW (Fig.3)
The cartridge fitted in this mixer has been factory pre-set to deliver the maximum flow of water when the mixer handle is in the fully open
position, however, the cartridge is also fitted with a water saving feature. If this feature is enabled, when the handle lever is released from
its maximum flow position it will automatically return to a pre-set reduced flow position.
This water saving feature can be enabled by adjusting the cartridge as follows:-
Carefully remove plug (1) before using a 2.5mm allen key (2) to loosen grub screw (3) and remove handle (4). (See details on side 1 of this sheet.)
Using a small thin flat bladed screwdriver, adjust screw (8) in a clockwise direction to reduce the flow when the handle lever is released.
To return to the factory pre-set maximum flow position, adjust the screw (8) anti-clockwise until the water saving feature is disabled.
Note:- Start by rotating the Screw (8) in small amounts then check the flow of water with the handle lever in the fully open released position.
Readjust the screw until the desired water flow is achieved.
Locate and hold the handle (4) onto the cartridge (9), then tighten grub screw (3). Replace plug (1), taking care that the red indication is to the left.