INSTALLATION AND OPERATION MANUAL
Port Configuration Window
The "Port Configuration" window enables to configure a single port or view its status.
User Input
Port
Enter the port number for which configuration needs to be changed or status needs to be
viewed.
Detection Type
Selects the PD detection type to be used:
» "None" for bypassing detection
» "2-point" for 2-point detection
» "4-point" for 4-point detection
» "4-point+legacy" for 4-point followed by legacy.
» "2-point+legacy" for 2-point followed by legacy
» "Legacy" for legacy detection only.
The "Legacy" option will be considered the next time detection is performed on those ports.
This will not affect ports in delivering state. To perform detection on a perform disable and
enable the port again.
Classification
Selects the PD classification type to be used:
» "Bypass" for ignoring classification.
» ".3af" for IEEE 802.3af classification signature
Tech SupporT: 1.888.678.9427
Figure 10: Port Configuration TAB Screen Shot