Comnet CNMC2+1SFP/M Manuel d'installation et d'utilisation - Page 4
Parcourez en ligne ou téléchargez le pdf Manuel d'installation et d'utilisation pour {nom_de_la_catégorie} Comnet CNMC2+1SFP/M. Comnet CNMC2+1SFP/M 6 pages. 2 channel 10/100/1000 mbps ethernet electrical to optical media converter
INSTALLATION AND OPERATION MANUAL
FIGURE 5 – Indicating LEDs
LINK
GREEN
Communication link has been
established over optical fiber. Flashes
when data is being transmitted.
YELLOW
N/A
RED
N/A
OFF
Communication link has
not been established.
FIGURE 6 – DIP Switches (CNMC2+1SFP Standard Size Units Only)
SW
NAME
1
LINK FAULT ENABLE PORT 1
2
LINK FAULT ENABLE PORT 2
3
FFE
4
MUX
5
DEMUX
6
100/1000
FIGURE 7 – DIP Switches (CNMC2+1SFP/M Small Size Units Only)
SW
NAME
1
LINK FAULT ENABLE PORT 1
2
LINK FAULT ENABLE PORT 2
3
MUX
4
DEMUX
5
100/1000
FIGURE 8 - Fault Relay Operation (CNMC2+1SFP Standard Size Units Only)
The fault relay is normally closed and will open on any of the following alarm conditions:
- Link Fault is enabled on the remote CNMC2+1SFP unit and a copper port has been disconnected.
- Link Fault is enabled on the local CNMC2+1SFP unit and a copper port has been disconnected.
- Fiber Fault is enabled on the local CNMC2+1SFP unit and the fiber link is down or the power has been lost
to either the local or remote CNMC2+1SFP unit.
TECH SUPPORT: 1.888.678.9427
STATUS (See Figures 8 & 9)
No Fault conditions detected
N/A
Fault detected (One or more DIP Switch relays
must be enabled)
Unit not correctly powered up
OFF (DOWN)
Link Fault Pass-Through Disabled
Link Fault Pass-Through Disabled
Fiber Fault Relay Disabled
MUX Disabled
DEMUX Disabled
1000 MBPS (Unit must be restarted for a
speed change to take effect)
OFF (DOWN)
Link Fault Pass-Through Disabled
Link Fault Pass-Through Disabled
MUX Disabled
DEMUX Disabled
1000 MBPS (Unit must be restarted for a
speed change to take effect)
POWER
Unit is correctly powered up
N/A
N/A
Unit not correctly powered up
ON (UP)
Link Fault Pass-Through Enabled.If the Copper Port is Down or Not Connected, the
Optical Port will turn on and off at a ~1 sec rate to indicate copper port 1 fault.
Link Fault Pass-Through Enabled.If the Copper Port is Down or Not Connected, the
Optical Port will turn on and off at a ~1 sec rate to indicate copper port 2 fault.
Fiber Fault Relay Enabled. If the optical link is lost or there is a power failure then the alarm
relay output will be triggered.
Mux Enabled. All Ethernet traffic is diverted from the copper ports to the fiber port,
copper-to-copper traffic will be disabled.
DeMux Enabled. When two CNMC2+1SFP units are connected via fiber and both have
DeMux enabled, traffic from Port 1 will go to Port 1 and traffic from Port 2 will go to Port 2
only, functioning like two separate media converters over one fiber.
100 MBPS (Unit must be restarted for a speed change to take effect)
ON (UP)
Link Fault Pass-Through Enabled.If the Copper Port is Down or Not Connected, the
Optical Port will turn on and off at a ~1 sec rate to indicate copper port 1 fault.
Link Fault Pass-Through Enabled.If the Copper Port is Down or Not Connected, the
Optical Port will turn on and off at a ~1 sec rate to indicate copper port 2 fault.
Mux Enabled. All Ethernet traffic is diverted from the copper ports to the fiber port,
copper-to-copper traffic will be disabled.
DeMux Enabled. When two CNMC2+1SFP units are connected via fiber and both have
DeMux enabled, traffic from Port 1 will go to Port 1 and traffic from Port 2 will go to Port 2
only, functioning like two separate media converters over one fiber.
100 MBPS (Unit must be restarted for a speed change to take effect)
CNMC2+1SFP[/M]
ETHERNET LINK/ACTIVITY
Unit is operational
Fiber failure or copper failure (Link
Fault DIP Switch must be Enabled / ON)
N/A
Unit not correctly powered up.
INS_CNMC2+1SFP Series 10/18/14 PAGE 4