Comnet FDW1000S/R Manuel d'installation et d'utilisation - Page 8
Parcourez en ligne ou téléchargez le pdf Manuel d'installation et d'utilisation pour {nom_de_la_catégorie} Comnet FDW1000S/R. Comnet FDW1000S/R 12 pages. Optical wiegand, magstripe & f/2f data extender
INSTALLATION AND OPERATION MANUAL
SETUP EXP100
Configuration Process:
1. With power off, set the Dip Switch on the Central unit according to the table below.
2. Apply Power. The Status LED should display a steady Green indication.
3. Remove Power. Set Dip Switch #1 to OFF. Any other Dip Switches can now be set as required (Reader family/
Pullup resistors). The FDW1000/C is now configured. No configuration is necessary for the FDW1000/R.
4. Configure the EXP100 expansion module according to that product's manual.
5. Connect the Expansion mofules into the system as indicated in Figures 15 and 16 beginning on Page 9.
Operation:
The FDW1000 series Remote and Central units will operate as a standard pair, with all of the I/O and data terminals
available for use with readers and access control systems. WIth the expansion module:
•
The Status LED on the FDW1000 units will indicate the status of the main (gateway) communication link only.
•
The Alarm relay on the Central gateway unit will deactivate (indicate alarm condition) when the communication
fails between the gateway units or ANY of the Remote or Central EXP100 units.
FIGURE 13 – FDW1000/C SWITCH SETTINGS WHEN USED WITH EXP100
ON
TECH SUPPORT: 1.888.678.9427
1
Gateway Only - No EXP
ON
1 EXP100 Pair Used
ON
2 EXP 100 Pairs Used
ON
3 EXP Pairs Used
ON
4 EXP Pairs Used
ON
5 EXP Pairs Used
ON
6 EXP Pairs Used
ON
7 EXP Pairs Used
ON
Switch
2
3
4
5
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
FDW1000(M,S)
6
7
8
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
INS_FDW1000_EXP100_REV– 04/25/12 PAGE 8