cabinet temperature. The electronic controller has been programmed to maintain an average of the set
temperature.

POWER- OFF AND ON

Press button "START" to switch ON/OFF.
Press +or - or temperature setting.
Press setting and choose ECO(Energy-saving) or MAX (Fast cooling). Factory setting is MAX
Long press "SET" for three seconds. When H flashes on the screen, select three battery protection modes
H(High), M(Middle) and L(Low) by pressing setting button again. Factory setting is H.5. Input voltage
Note: Maximum temperature settings are from -20°C to +20°C.
1. Press power button & the fridge will go into standby mode then switch off after 5 seconds
2. Press the power button & the fridge will re-start with the previously selected settings
3. The temperature display will flash when selecting the temperature & return to solid display when showing the
actual internal temperature

CABINET TEMPERATURE- SETTING

1. Adjust the temperature by pressing the + button to increase or the - button to decrease the temperature.
2. The temperature display will flash when selecting the temperature & return to solid display when showing the
actual internal temperature

BATTERY MONITOR- SETTING

In the standby mode, press and hold "setting" for 5 seconds to enter the battery protection setting mode, and press
+ or - to set the (H) high, (M) middle and (L) low battery protection.
12V DC input
LOW
MEDIUM
HIGH
24V DC input
LOW
MEDIUM
HIGH
Cut out
9.6V
10.1V
11.1V
Cut out
21.3V
22.3V
24.3V
6
Cut in
10.9V
11.4V
12.4V
Cut in
22.7V
23.7V
25.7V