Compac Master MR80S Instructions d'installation et de mise en service - Page 10

Parcourez en ligne ou téléchargez le pdf Instructions d'installation et de mise en service pour {nom_de_la_catégorie} Compac Master MR80S. Compac Master MR80S 17 pages.

Parameter Switch Settings

10.3
10.3.1
Setting the Pump Number
This must be set at the pump, for each hose, so that communications with
a controller can take place. The location of this switch is shown in the
diagram below.
Depress the Parameter Switch nine (9) or more times until the message
'PnA XX' appears in the litres display window. When the switch is
pressed again 'Pnb XX ' will appear on the display. These two options
will toggle each time the switch is pressed. To alter either of the pump numbers, press and hold
the Parameter Switch when the pump number to be altered appears on the display. This number
will then increment. The switch should be released when the desired pump number is displayed.
The value of the displayed number will then be stored in the C4000 memory as the pump
number for that hose.
NOTE: For a single hose only 'Pn" will appear
10.3.2
Setting the Price
Using the Parameter Switch, follow the chart to set the price for the hose(s) in question.
Step
ACTION
1
Ensure that the nozzle is hung up
2
Press and Hold the Parameter switch until the
"Price per litre" is displayed.
3
Press and hold the Parameter switch.
4
When the digit is correct, release the Parameter
switch.
5
Repeat steps 3 and 4 for each digit of the 'Price per
litre'.
6
Press and release the Parameter switch 8 or more
times in quick succession
7
Repeat steps 3 to 5 above.
\\Cilaklfs1\shrdata\Masters\Installation Sheets\Master & Premier\MR40S MR80S Installation
RESULT
Dispenser in idle state
The price for side 'A' is shown as 'PX.XXX' on the
litres display and 'PrA' is displayed on the money
display.
A digit, of the displayed 'Price per litre', will begin to
increment.
NOTE: the C4000 will reset itself if the Parameter
switch is left for more than 60 seconds.
Continue for Dual hose units
The price for side 'B' is shown as 'PX.XXX' on the
litres display and 'Prb' is displayed on the money
display.
Sheet.doc
Page 10 of 17