Disabling some of the functions of the COMPACT
Each of the three functions Charger, Inverter and Transfer can be individually disabled. This is required
for some installations
different possibilities shown in the following diagram. In this programming mode the 3 LEDs show the
different types of programs: LED 2 'Charger,' LED 7 'Transfer, and LED 9 ' Inverter'.
To change the program press button 20 until you reach the right function illustrated in the diagram
below. Once finished programming wait 10 seconds and the change will be stored. Once back in the
normal user mode, the disabled functions are indicated by flashing LEDs.
Diagram of the different modes
1
AC IN –
CHARGER-
2
1
AC IN –
CHARGER-
2
1
AC IN –
CHARGER-
2
1
AC IN –
CHARGER-
2
.
Press and hold button 20 for more than 2 seconds and you have access to the
Sinewave Inverter, Battery Charger
- Indicates LED OFF
- Indicates LED Flashing
- Indicates LED ON
- AC OUT
8
-INVERTER
9
- AC OUT
8
-INVERTER
9
- AC OUT
8
-INVERTER
9
- AC OUT
8
-INVERTER
9
- 14 -
All the functions are
enabled.
This is the factory
setting
The Inverter is disabled.
Only the Transfer system
and the Battery charger are
operational
The Battery charger and the
Transfer system are
disabled. The Inverter will
operate continuously even if
there is correct AC voltage
at the AC INPUT
The Inverter and the Battery
charger are disabled. Only
the Transfer system is
enabled if the correct
voltage and frequency
appear at the AC INPUT.