AirTech 3AV255 Instructions de réparation - Page 3
Parcourez en ligne ou téléchargez le pdf Instructions de réparation pour {nom_de_la_catégorie} AirTech 3AV255. AirTech 3AV255 10 pages.
Repair Instructions 3AV 30 - 430
General Remarks
Before disassembly the pump, isolate the electrical input and disconnect the operation liquid connec-
tion, and inlet and outlet connections. Disassemble and reassemble the pump on a level surface. Mark
all parts as they become accessible during disassembly to ensure correct positioning for reassembly.
Before starting disassembly, collect the parts, materials and standard tools, which are required for
disassembly and reassembly of the pump
Special Tools, Parts and Materials
Feeler gauge
Molykote G-n Paste or equivalent
Liquid sealant e.g. Epple 32
Metal straight edge
Loctite 242 and Primer
Solvent such as kerosene
Dismantling Pump
1
•
Remove five fixed pump casing screws (901)
•
Remove pump casing (101)
•
Remove inter casing (137)
Disassembling Inter Casing from Pump Casing
1.1
1.1.1
Type 3AV 95/3AV 130/3AV 155/3AV 330/3AV 430
•
Remove fixed hexagon socket countersunk head screw (901.2) at inter casing (137)
•
Remove inter casing (137) from pump casing (101)
1.1.2
Type 3AV 255
•
Remove fixed screwed plug (903) at pump casing (101)
•
Remove fixed hexagon socket head cap screw (914) at pump casing (101)
•
Turn around pump casing (101) and inter casing (137)
•
Remove inter casing (137)
.
3