Dresser DCR Series Manuel d'installation - Page 11
Parcourez en ligne ou téléchargez le pdf Manuel d'installation pour {nom_de_la_catégorie} Dresser DCR Series. Dresser DCR Series 16 pages. Rcs actuators
REQUEST A QUOTE AT WWW.AUTHORIZEDPARTS.COM
MAR8RH Parts List & Technical Data
4.88
For Cover Removal
7
7.47
.56
.375
Technical Data
Voltage: 115 vac 60/50 Hz., 1 Phase—Standard
Operation: Reversible
Limit Switches: 15 Amps at 125 and 250 Vac UL &
CSA Listed
Ambient Temperature: -40°F to +150°F.*
Lubrication: High temperature grease for gears;
Self-lubricating bearings
Mounting positions: Universal
Weight: 6.5 lbs.
* The addition of a heater is recommended for all outdoor
installations and for all applications that are exposed to high
humidity or temperatures below 32°F. (Consult factory)
6
9
1
8
3
3/4" 14 N.P.T.
2 Places
Of Actuator
.375
#10-24.50 Deep
4 Places
.750.
1.500 Sq.
.436/.432
Across Flats
(Output Shaft)
Parts List
Loc. No.
1
2
3
4
5
6
7
8
9
11
4
2
5
6.12 Dia.
.562/.561
Description
Cover
O-Ring
Base
Gear Plate
Geartrain Assembly
Terminal Block – 6 Point
Motor
Cam-Adjusting
Capacitor
3.12
6.25
Qty.
Part No.
1
10-212
1
14-134
1
33-417
1
33-420
1
C/F
1
72-01
1
31-01M
2
68-03-10
As Req'd