Andrew TYPE 120 Manuel d'instructions de montage - Page 4
Parcourez en ligne ou téléchargez le pdf Manuel d'instructions de montage pour {nom_de_la_catégorie} Andrew TYPE 120. Andrew TYPE 120 8 pages. 90cm, 1.0m & 1.2m smc antenna system
Également pour Andrew TYPE 120 : Manuel d'instructions de montage (16 pages)
GROUND POLE INSTALLATION
2 " O.D. x 72" LONG
2 " O.D.
PIER
FOUNDATIONS
1" to 2"
SLOPE FOR
WATER RUN OFF
37
72
GRADE
36
OVAL END
d
MIN.
BELOW
FROST LINE
DIA.
PIER FOUNDATIONS
ANT
WIND VEL.
DIM "d"
80 MPH
9"
90 MPH
11"
90cm
100 MPH
13"
110 MPH
15"
125 MPH
18"
80 MPH
10"
1.0M
90 MPH
13"
100 MPH
15"
108 MPH
16"
POLE SPECIFICATIONS:
2" SCH 40 2 " O.D. x .154 Wall x 72" Long Steel - CM PN 611652931 w/Oval End and
Powder Paint Finish.
1. When wind velocity exceeds 108 MPH on the 90cm antenna at heights shown, the
ground pole must be a heavy wall pipe as follows: 2" pipe (2 " O.D.) Schedule 80
(.218" wall thickness) and purchased locally. Field weld
Fig. 1.0 to prevent rotation in the concrete or use 3" O.D. ground pole and AZ/EL cap.
2. These charted values based on using Model 611652931 ground pole, 2.375 O.D. x
1.54 wall. When wind velocity exceeds 108 MPH, use 3" O.D. ground pole and AZ/EL
cap.
3. Pole and foundation design based on the following criteria: (a) Uniform Building
Code Exposure C and 1.5 stability factor, (b) Vertical soil pressure of 2000 pounds
per square foot, (c) Lateral soil pressure of 400 pounds per square foot, (d) Concrete
compressive strength of 2500 pounds per square inc h in 28 days.
4. CAUTION - The foundation design shown does not represent an appropriate design
for any specific locality since soil conditions vary and may not meet design criteria
given in Note 1. You should consult a local professional engineer to determine your
soil conditions and appropriate foundation.
2
2 " O.D.
NOTE:
48" may be
increased, concrete
and length of rebar
DEEP
will increase
FROST LINE
accordingly.
FOUNDATIONS
1" to 2"
SLOPE FOR
37
WATER RUN OFF
72
GRADE
48"
(SEE NOTE)
OVAL END
1-1.5"
APPROX.
d
2"
MIN.
BELOW
DIA.
FROST LINE
(4) #3 x 24" MIN.
AT 90˚ APART
(SEE NOTE)
DEEP FROST LINE FOUNDATIONS
CONC VOL.
DIM "d"
CONC VOL.
GROUND POLE
1.5 FT
3
7"
1.2 FT
3
2.2 FT
3
7"
1.2 FT
3
Mo. 611652931
3.0 FT
3
8"
1.5 FT
3
4.0 FT
3
10"
2.4 FT
3
SEE NOTE 1
5.8 FT
3
12"
3.5 FT
3
1.8 FT
3
7"
1.2 FT
3
Mo. 611652931
3.0 FT
3
8"
1.5 FT
3
4.0 FT
3
9"
1.9 FT
3
SEE NOTE 2
4.6 FT
3
10"
2.4 FT
3
.21
.21
x 1
x 5 key as shown in
FIG. 1.0
CLAMP
SURFACE
14
6
9
7
10
FIG. 4.1 - ANTENNA, ANTENNA FEED (LNB) & FEED SUPPORT LEGS
FIELD WELD
KEY
x 1
x 5
6"
APPROX.
PARTS AND HARDWARE LISTING
12
13
11
9
6
6
4
Junction Block (9)
ITEM
DESCRIPTION
4
LEG BOTTOM (90cm)
4
LEG-BOTTOM-FEED (1.0m)
4
LEG-BOTTOM-FEED (1.2m)
5
REFLECTOR-SMC 1.0m
5
REFLECTOR-SMC 1.2m
5
REFLECTOR-SMC 90cm
6
LEG-SIDE-FEED (1.0m)
6
LEG-SIDE-FEED (1.2m)
6
LEG-SIDE-FEED (90cm)
7
BOLT-HEX M6 x 30
8
WASHER, FLAT
" x
"
9*
BLOCK-JUNCTION
10
WASHER-FLAT
" x
" O.D.
11*
CLAMP-HALF-JCT.
12*
BOLT HH M6 x 20
13*
WASHER-FLAT M6 x
" O.D.
14*
KU-FEED ASSY.
15
SCREW-TPG-SPL M6
*Provided in feed assembly.
5
8
7
15
QTY.
1
1
1
1
1
1
2
2
2
4
2
1
2
1
2
2
1
1
11