21
Component units
(380 V, 60 Hz)
1
K1
Relay, extraction
K2
Relay, brake
T1
Auxiliary transformer - supplies power to the electronics unit, and provides control
voltage 24 V AC to components. The transformer is connected for the mains
voltage 380 V.
F1
Precision fuse M 0.2 A/500 V - protects primary side of auxiliary transformer.
F2
Precision fuse T 2.5 A/500 V - protects secondary side of auxiliary.
SW1
Microswitch - detects position of lid lock.
CP
Control panel with push-button and indicator lights.
Y1
Lock magnet - operate the lid lock.
MP
Circuit board.
X1
Terminal connection.
1
CP
MP
F2
T1
F1
21.2
21. Automatic unit
Service
manual
Y1
Lid lock
SW1
K2
K1
X1
487 03 29 91