Atlantic alfea S8 Manuel d'utilisation - Page 13

Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation pour {nom_de_la_catégorie} Atlantic alfea S8. Atlantic alfea S8 16 pages. Alféa s series heat pump air/water split, single service

Split system
Line
Function
Holidays, heating circuit 1
641
Preselection
642
Start (Day / Month)
643
End (Day / Month)
648
Operating level (during the holidays)
Holidays, heating circuit 2
If the installation consists of 2 heating circuits (Only with the 2
651
Preselection
652
Start (Day / Month)
653
End (Day / Month)
658
Operating level (during the holidays)
Heating Circuit 1
710
Comfort heating setpoint
712
Reduced setpoint
714
Frost protection setpoint
Cooling circuit 1
901
Operating mode
902
Comfort cooling setpoint
907
Release
If the installation is fitted with a DHW tank, set the parameter 907 to "Time program 5 / Cooling"
(In order to activate cooling only during the day and leave the DHW system to operate during the night).
Heating Circuit 2
If the installation consists of 2 heating circuits (Only with the 2nd circuit kit option).
1010
Comfort heating setpoint
1012
Reduced setpoint
1014
Frost protection setpoint
Domestic hot water (DHW) (Only with the DHW kit option)
1610
Nominal setpoint
The backup electrical system is required to reach this level.
1612
Reduced setpoint
Swimming pool (Only with swimming pool kit option)
2056
Setpoint source heating
Fault
6711
Reset HP
Service / Special operation
7141
Emergency operation
Off : The heat pump does not use the backup electrical heating system or the boiler connection when a fault occurs (error 370)
On : The heat pump uses the backup electrical system or the boiler connection when a fault occurs (error 370).
In the "On" position, the energy costs can be onerous if the error is not eliminated.
Operation manual "1328 - EN"
Setting range
or display
Period 1 to 8
01.01... 31.12
01.01... 31.12
Frost protection, Reduced
circuit kit option).
nd
Period 1 to 8
01.01... 31.12
01.01... 31.12
Frost protection, Reduced
from reduced setpoint to 35°C
from frost protection setpoint...
to comfort setpoint
from 4°C...
to reduced setpoint
Off, Automatic
17... 40 °C
24h/day, Time program HC,
Time program 5 / Cooling
from reduced setpoint to 35°C
from frost protection setpoint...
to comfort setpoint
from 4°C... to reduced setpoint
Reduced setting (line 1612)...
to 65 °C
8 °C...
to Nominal setpoint (line 1610)
8... 35 °C
No, Yes
Off, On
Setting
Basic
increment
setting
Period 1
1
1
Frost
protection
Period 1
1
1
Frost
protection
0,5 °C
20 °C
18 °C
0,5 °C
0,5 °C
8 °C
Off
0,5 °C
24 °C
Time
program 5
0,5 °C
20 °C
0,5 °C
18 °C
0,5 °C
8 °C
1
50 °C
1
25 °C
22 °C
No
Off
- 13 -