Atlantic Boilers RS TURBOFLOW DN 100 S700+ Manuel d'utilisation et d'entretien - Page 6

Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation et d'entretien pour {nom_de_la_catégorie} Atlantic Boilers RS TURBOFLOW DN 100 S700+. Atlantic Boilers RS TURBOFLOW DN 100 S700+ 18 pages. Plate heat exchangers

1.9 - Nameplate
• Stuck to the frame plates.
2 - STORAGE
• Store the heat exchangers in a dry room protected from the weather and maintained at a
temperature between +5°C and +35°C.
• The heat exchangers must be placed on blocks dimensioned and adjusted to ensure adequate
stability and levelness, on a floor protected from caving in. Make sure that they do not touch each other
and that they are not in direct contact with the floor and any walls.
• Protect them from impacts, dust and from the risk of liquid or solid deposits and make sure that
nothing is placed on them.
• Do not remove the protection on the end of the pipes until you are ready to make the hydraulic
connections.
• All unused spare parts must be stored away from damp, light, and dust, and protected from impacts.
• Gaskets and gasketed plates must be stored in appropriate boxes at a temperature of between
10°C and 30°C. Maximum shelf-life: 12 months.
ATLANTIC BOILERS, PO BOX 11, ASHTON UNDER LYNE, OL6 7TR T: 0161 621 5960 E: [email protected] www.atlanticboilers.com
• MANUFACTURING YEAR: Year of manufacture.
• MODEL: Heat exchanger model and product configuration.
• SERIAL No.: Production number, to identify your heat
exchanger.
• DATE: Date of manufacture.
• REF.: Eventual notes and/or different references.
• ALLOWABLE TEMPERATURE MIN. / MAX. (TS):
Minimum and maximum allowable temperatures.
• ALLOWABLE PRESSURE MIN. / MAX. (PS):
Minimum and maximum allowable pressure, in bar.
• TEST PRESSURE (PT): Test pressure, in bar.
• VOLUME: Total capacity of the heat exchan-
ger, in litres.
• PED CLASSIFICATION: Risk category of the
heat exchanger (hazard group and physical
state of the fluid).
• CE MARKING: Only the heat exchangers
classified in PED risk category I, II, III or IV
can be CE marked. The identification number of the Noti-
fied Body will appear near to the CE Mark symbol for heat
exchangers classified in risk category II, III or IV.
• CIRCULATION: 1 indicates the inlet and outlet of the primary
loop. 2 indicates the inlet and outlet of the secondary loop.
• TIGHTENING MEASURE: Minimum and maximum tightening
dimension (d) between the plates, in mm.
• WEIGHT (EMPTY): Empty weight of the heat exchanger,
in kilograms.
d
33