Également pour Electrolux ICON RH30WC60GS : Catalogue des pièces d'usine (4 pages), Manuel d'installation, d'utilisation et d'entretien (21 pages), Manuel d'installation, d'utilisation et d'entretien (22 pages), Brochure & Specs (2 pages), Manuel d'utilisation et d'entretien (44 pages), (anglais) Installation, Use and Care Guide (22 pages), (French) Manual D’installation, Utilisation Et D’entretien (22 pages)

Electrolux ICON RH30WC60GS Manuel d'installation, d'utilisation et d'entretien

Installing the hood

For the most e cient air ow exhaust, use a
straight run or as few elbows as possible.
Vent unit to outside of building and recirculating.
On avarage 2 to 3 hours are necessary to com-
plete installation (without considering cut to be
done on wall and or on cabinet, installation of
ducts , conduit and electrical connections to the
mains).
The hood is tted with Screws and Drywall
Anchors suitable for most surfaces, consult a
Quali ed Installer, check if they perfectly t with
your cabinet/wall.
Do not use ex ducting.
COLD WEATHER installations should have an
additional backdraft damper that is already installed
to minimize backward cold air ow and a nonmetallic
thermal break to minimize conduction of outside
temperatures as part of the ductwork. The
damper should be on the cold air side of the
thermal break.
The break should be as close as possible to
where the ducting enters the heated portion of
the house.
Make up air: Local building codes may require the
use of Make-Up Air Systems when using Ducted
Ventilation Systems greater than speci ed CFM of
air movement.
The speci ed CFM varies from locale to locale.
Consult your HVAC professional for speci c
requirements in your area.
T T T T T ypical installation
ypical installation
ypical installation
ypical installation
ypical installation
Min installation height from the range top to the
bottom of the hood is 30" if a gas range is used
or 24" to 30" if an electric range is used.
These hoods ar
These hoods ar
These hoods ar e not r
These hoods ar
These hoods ar
e not r
e not r
e not recommended to be used
e not r
ecommended to be used
ecommended to be used
ecommended to be used
over indoor grills.
over indoor grills.
over indoor grills.
over indoor grills.
over indoor grills.
ecommended to be used
Installing the hood
The hood may be installed onto a wall and vented to
the outdoors, or it can be installed for recirculating
operation (recirculating accessories not supplied with
the hood).
This hood can be installed over any electric and gas
cooktop/range.
It can not be installed over any pr ofessional
It can not be installed over any pr
It can not be installed over any pr
It can not be installed over any pr
It can not be installed over any pr
cooktop / range.
cooktop / range.
cooktop / range.
cooktop / range.
cooktop / range.
Installing pr
Installing pr
eparation
eparation
Installing pr

Installing preparation

Installing pr
eparation
eparation
Advance planning
Advance planning
Advance planning
Advance planning
Advance planning
Determine the exact location of the vent hood.
Plan the route for venting exhaust to the
outdoors.
Use the shortest and straightest duct route
possible.
Refer to " Ductwork installation guidelines
Ductwork installation guidelines
Ductwork installation guidelines
Ductwork installation guidelines"
Ductwork installation guidelines
paragraph for further informations.
Install a wall cap with damper or roof cap at the
exterior opening. Order the wall or roof cap and
anytransition needed in advance.
Use 8" round metal ductwork only.
W W W W W all framing for adequate support
all framing for adequate support
all framing for adequate support
all framing for adequate support
all framing for adequate support
This vent hood is heavy.
'Adequate structure and support must be
provided in all types of installations. The hood
must be secure to vertical studs in the wall, or to
a horizontal support.
The vent hood should be on site before nal
framing and wall nishing. This will help to
accurately locate the duct work and electrical
service.
Installation will be easier if the vent hood is
installed before the cook-top and countertop are
installed.

Removing the packaging

Removing the packaging
Removing the packaging
Removing the packaging
Removing the packaging
Remove carton carefully, Wear gloves to protect
against sharp edges.
Remove the protective lm covering the product
before putting into operation.