Electrolux LFC319X Manuel de l'utilisateur - Page 4
Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Electrolux LFC319X. Electrolux LFC319X 12 pages.
Également pour Electrolux LFC319X : Manuel d'installation (16 pages)
• WARNING: Failure to install the screws or fixing device in
accordance with these instructions may result in electrical
hazards.
• Do not use adhesives to fix the appliance.
• The minimum distance between the hob surface on which
the pans stand and the lower part of the appliance shall be
at least 65 cm, unless otherwise specified in the installation
instructions for the appliance or hob.
• The discharge of air must comply with local authorities
regulations.
• Ensure good air ventilation in the room where the appliance
is installed to avoid the backflow of gases into the room
from appliances burning gas or other fuels, including open
fires.
• Make sure that the ventilation openings are not blocked and
the air collected by the appliance is not conveyed into a
duct used to exhaust smoke and steam from other
appliances (central heating systems, thermosiphons, water-
heaters, etc.).
• When the appliance operates with other appliances the
maximum vacuum generated in the room should not exceed
0.04 mbar.
• If the supply cord is damaged, it must be replaced by the
manufacturer, its Authorised Service Centre or similarly
qualified persons to avoid an electrical hazard.
• If the cord set is damaged, it must be replaced by a special
cord set available from the manufacturer or its Authorised
Service Centre.
• If the appliance is connected directly to the power supply,
the electrical installation must be equipped with an isolating
device that allows to disconnect the appliance from the
mains at all poles. Complete disconnection must comply
with conditions specified in the overvoltage category III. The
means for disconnection must be incorporated in the fixed
wiring in accordance with the wiring rules.
• Do not flambé under the appliance.
4
ENGLISH