Atlantic Ultraviolet MIN-6 Manuel du propriétaire - Page 8

Parcourez en ligne ou téléchargez le pdf Manuel du propriétaire pour {nom_de_la_catégorie} Atlantic Ultraviolet MIN-6. Atlantic Ultraviolet MIN-6 16 pages. Germicidal ultraviolet water purifiers
Également pour Atlantic Ultraviolet MIN-6 : Manuel du propriétaire (16 pages), Manuel du propriétaire (20 pages)

L
I
AMP
NSTALLATION OR
Step 1 - Remove Ground Connector
Step 3 - Remove Socket
1.
Disconnect power to water purifier, and remove ground connector from the chamber.
2.
Remove easy-off end cap by pulling cap off static gland nut.
3.
Carefully withdraw lamp approximately 2 inches from chamber. While holding lamp end, remove lamp socket
from exposed lamp end.
4.
Carefully withdraw lamp from chamber. Be sure to withdraw lamp straight out without angling until completely
clear of quartz sleeve.
!
CAUTION:
replacing lamp.
5.
Reinstall lamp in reverse order.
!
WARNING:
water purifier until lamp and easy-off end caps have been properly reinstalled.
8
R
EPLACEMENT
Figure 2 - Lamp Replacement
Lamp and quartz sleeve are easily damaged. Exercise care when removing or
Germicidal ultraviolet rays are harmful to eyes and skin. Do not restore power to
Step 2 - Remove End-Cap
Step 4 - Remove Lamp