1. Guardian™ Ultraviolet Monitor*: Visually indicates the level of germicidal ultraviolet energy that penetrates the
quartz sleeve and the water within the water purifier. The ultraviolet monitor is capable of operating an optional
audio alarm and/or solenoid valve. The ultraviolet monitor will detect reduction of ultraviolet levels due to:
• Fouling or deposits on the quartz sleeve.
• Poor ultraviolet transmission through the water; color, turbidity, and organic or other impurities in the water can
reduce or interfere with the transmission of ultraviolet rays.
• Lamp outage, component or power failure.
• Depreciation of the lamp output due to usage or other cause. Lamp output gradually depreciates with use. Lamp
replacement is recommended once each year.
2. Sentry™ Safety Sensor: Pilot lamps provide constant visual monitoring of normal operation. In the event of power
or lamp failure the safety sensor indicates an alarm condition. The safety sensor is capable of operating an optional
audio alarm and/or solenoid valve.
3. Steralert™: Lamp Status Alarm produces a high pitched, pulsed tone when the purifier is no longer functioning due
to lamp or power failure.
4. SureFLO™: Flow Control Valve, limits water flow to the rated capacity of the purifier. The flow control valve is
located in line prior to the water purifier, and should be protected from ultraviolet exposure by the use of a
90-degree elbow fitting between the flow control valve and the water purifier.
5. Audio Alarm*: Activated by the Ultraviolet Monitor or Safety Sensor, alerts the user to any malfunction detected.
6. Solenoid Valve*: Operated in conjunction with the Ultraviolet Monitor, Safety Sensor or Time Delay Mechanism,
this valve prevents water flow through the water purifier when an abnormal condition is detected or in the event of
power failure.
7. Elapsed Time Indicator: A non-resettable display of the water purifier operating hours. Useful for scheduling and
recording maintenance and lamp replacement.
8. Time Delay Mechanism*: Provides a 2-minute warm up period during which the ultraviolet lamp achieves its full
germicidal output before the water is allowed to flow through the water purifier. The time delay mechanism is used
in conjunction with, and is electrically connected to the Solenoid Valve.
9. Wall Mount Kit: (S2400C) Stainless steel wall brackets provide quick and easy installation and professional finish.
Pre-drilled and ready to install. Optimizes free air circulation to cool ballast housing.
*Use of this option is recommended by U.S. Public Health Service "Criteria for Acceptability of an Ultraviolet
Disinfection Unit." Originally issued April, 1966.
OPTIONAL ACCESSORIES
Optional Accessories
Guardian™ Ultraviolet Monitor - Analog/Digital
Sentry™ Safety Sensor
Steralert™
Audio Alarm
Elapsed Time Indicator - Universal Input
Time Delay Mechanism
Wall Mounting Kit
Solenoid Valve - Brass (1-1/2")
Solenoid Valve - Brass (1-1/2")
Solenoid Valve - Brass (2")
Solenoid Valve - Brass (2")
™
SureFLO
Flow Control - PVC (2")
™
SureFLO
Flow Control - Stainless Steel (2")
™
SureFLO
Flow Control - PVC (2" Union)
O
PTIONS
Table 2 - Optional Accessories
Available for:
S2400C, S5,000C - S25,000C
S2400C, S5,000C - S25,000C
S2400C, S5,000C - S25,000C
S2400C, S5,000C - S25,000C
S2400C, S5,000C - S25,000C
S2400C, S5,000C - S25,000C
S2400C
S2400C
S2400C
S5,000C - S25,000C
S5,000C - S25,000C
S2400C
S2400C
S5,000C - S25,000C
Options are available for operation
at 120v 60Hz or 220v 50Hz.
Not all options may be available
for all models, consult factory for
availability.
Solenoid requires 10-PSI for
satisfactory operation.
Solenoid operates at 0-PSI and up.
Unless otherwise specified:
PVC flow controls are supplied.
All PVC and Stainless Steel flow
controls are male NPT.