PRODUCT APPLICATION
C
onstruCtion
The SANITAIRE
Room Air Sanitizer consists of:
®
•
STER-L-RAY
Germicidal Ultraviolet Lamp(s), which deliver germicidal ultraviolet energy at the specific wavelength of
®
254 nanometers (nm), which effectively destroys airborne microbes including: virus, bacteria, and mold spores.
•
Surelite
Electronic Ballast(s) capable of operating at 120v 50/60 Hz or 230v 50/60 Hz. Other power supplies may be
™
available. Contact factory for specifics.
•
A polished reflector, whose design and specular aluminum construction maximizes ultraviolet intensity within
the exposure chamber
•
A standard, NEMA 5-15, three-prong plug, and operates on 120VAC 60Hz single-phase standard household current. The
SANITAIRE
is also available for operation on 230VAC 50Hz.
®
•
Promate
permanent, washable, electrostatic intake filter(s), capable of removing airborne particles as small as 5 microns.
™
•
A louvered exhaust, which restricts ultraviolet radiation from passing into the room, protecting the room's occupants from
ultraviolet exposure.
•
A Promate
Sight Glass Assembly, which provides a safe visual indication of germicidal lamp(s) operation without the risk
™
of ultraviolet exposure.
•
An enclosure and access cover constructed of stainless steel, type 304. Stainless steel construction provides strength,
durability and lasting value.
•
An interlock safety switch. The interlock switch interrupts power to the sanitizer, when the access cover is removed from the
lamp/exposure chamber.
•
Molded rubber feet, for use on tabletops, shelves, etc. and standard wall mounting brackets (Models RS72, RS140 and RS435
only). These brackets allow the SANITAIRE
horizontal position. Optional mounting kits are available; consult our application specialists for specific details.
•
A .3-micron, 99.97% minimum efficiency, HEPA type, absolute filter (Model RSA760 only).
P
o
rinCiPle of
Peration
The SANITAIRE
design has been carefully conceived to provide germicidal ultraviolet exposure for air disinfection. The
®
dosage, as it applies to ultraviolet disinfection, is a function of time, and the intensity, of ultraviolet radiation, to which the air
is exposed. The exposure time, in seconds, is the total time it takes the air to move through the ultraviolet field, produced by the
germicidal lamp(s). Exposure time is related to the airflow rate; the higher the airflow, the lower the exposure time or the lower
the airflow, the higher the exposure time. The operation of the SANITAIRE
1. Air is drawn into the fixture
through the electrostatic filter(s).
2. The air is forced into the
exposure chamber, where it is
irradiated by the germicidal
ultraviolet lamp(s).
3. Sight glass provides a safe
visual indication of germicidal
lamp operation.
4. The purified air exits the fixture,
through the louvered exhaust
panel, located at the opposite
end of the fixture. In the case
of the SANITAIRE
RSA760, once through the
louvered exhaust panel, air
is forced through a .3 micron
HEPA filter and finally through
an electrostatic particulate filter
before exiting the fixture.
4
to be mounted to a wall, or other vertical surface, in either the vertical or
®
Figure 1 – SANITAIRE
Model
®
Room Air Sanitizer is as follows:
®
Room Air Sanitizer Operation (RS435 Shown)
®