MAINTENANCE
Always disconnect power to the Nutripure
The Nutripure
•
®
is designed to operate with a minimal amount of maintenance.
A regular cleaning cycle of the STER-L-RAY
•
filter(s) MUST be established, and carefully maintained, based on inspection and experience. The frequency of cleaning will
vary with the conditions surrounding each installation. It is recommended that the ultraviolet lamp(s) interior, sight glass, and
filters be cleaned at least once every three (3) months.
The STER-L-RAY
•
life of 10,000 hours. STER-L-RAY
in ultraviolet output will make it impractical to use past the manufacturer's rated life. For maximum efficiency lamp
replacement is recommended every 10,000 hours of operation or about one (1) year of continuous use.
•
Unless lamp replacement is due to failure or breakage, it is recommended that all lamps be replaced at the same time.
l
i
amP
nstallation
Always disconnect power to the fixture before performing any service or maintenance.
Ultraviolet lamps are easily damaged. Exercise care when handling lamps.
1.
Disconnect power to the sanitary conditioner and unplug from the electrical outlet.
Remove access cover. (Removal of the Nutripure
2.
lamps and blower. DO NOT attempt to bypass or circumvent the interlock switch or its safety feature.)
3. Remove STER-L-RAY
pin clears the stationary lampholder, pull STER-L-RAY
4.
Moisten a clean, lint-free cloth with denatured alcohol and clean lamp(s).
When STER-L-RAY
5.
interior of the Nutripure
6.
To remove any dust, dirt, fingerprints, smears, etc, from the outer surfaces of the conditioner, moisten a clean, lint-free cloth
with denatured alcohol and wipe down the conditioner. Buff out any streaks, left from the cleaning, using a soft dry cloth.
7. Install STER-L-RAY
the spring-loaded lampholder. Align lamp pin with stationary lampholder. Slowly ease the pressure until STER-L-RAY
lamp is fully seated in lampholders.
Verify that STER-L-RAY
8.
Repeat until all STER-L-RAY
9.
10. Install Access Cover. Restore power to the Nutripure
11. Wear personal protection equipment, then verify operation by viewing STER-L-RAY
operating properly, go to "Troubleshooting" section.
8
®
maintains a qualified team of application specialists that can provide technical assistance, which
®
Germicidal Ultraviolet lamp(s) used in the Nutripure
®
®
Lamp(s) may operate longer than their rated effective life, but the reduction
, r
,
ePlaCement
or
IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE FOLLOWING SAFETY
EQUIPMENT: SAFETY GLASSES OR A FACE SHIELD, AS WELL AS GLOVES.
lamp(s), carefully press lamp against the spring-loaded lampholder, when STER-L-RAY
®
®
lamp(s) have been removed, cleaned and safely set aside, remove any loose dust or dirt from the
®
with a soft dry cloth, or vacuum.
lamp(s), insert lamp pin into spring-loaded lampholder. Carefully press STER-L-RAY
®
®
lamp(s) is properly seated.
®
lamps have been cleaned and properly reinstalled.
Avoid exposure to direct or reflected germicidal ultraviolet rays. Germicidal
ultraviolet rays are harmful to the eyes and skin.
®
before performing any service or maintenance.
Germicidal Ultraviolet Lamp(s), interior, Promate
C
leaning
®
access cover will cause the interlock switch to interrupt power to the
lamp out, and away from Nutripure
®
®
.
TM
sight glass and intake
®
have a manufacturer's rated average effective
®
.
®
lamps(s). If the fixture is not
®
lamp
®
lamp against
®