Electrolux RH36PC60GSB Manuel d'utilisation et d'entretien - Page 29

Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation et d'entretien pour {nom_de_la_catégorie} Electrolux RH36PC60GSB. Electrolux RH36PC60GSB 42 pages. 36" and 42" island range hood
Également pour Electrolux RH36PC60GSB : Manuel d'installation, d'utilisation et d'entretien (21 pages)

Electrolux RH36PC60GSB Manuel d'utilisation et d'entretien
Installing the hood
Installing preparation
The vent hood should be on site before final
framing and wall finishing. This will help to
accurately locate the duct work and electrical
service.
Installation will be easier if the vent hood is
installed before the cook-top and countertop are
installed.
Ductwork and wiring locations:
Determine the exact location of the vent hood.
Plan the route for venting exhaust to the
outdoors.
Use the shortest and straightest duct route
possible.
For satisfactory performance duct run should not
exceed 100' equivalent length for any duct
configurations.
Refer to "Ductwork installation guidelines" chart
to compute the maximum permissible length for
duct runs to the outdoors.
Ductwork installation guidelines
For safety reasons, ducting should vent directly
outdoors (not into an attic, underneath the house,
into the garage or into any enclosed space).
Keep duct runs as short and straight as possible.
Duct fittings (elbows and transitions) reduce air
flow eficiency.
Back to back elbows and "S" turns give very poor
delivery and are not recommended.
A short straight length of duct at the inlet of the
remote blower gives the best delivery.
Transition to duct from the integral blower or
remote duct transition as close to the downdraft
as is possible.
In order of preference, use
1st. 10" round duct
2nd. 8" round duct
3rd. 3-1/4" x 14" duct
4th. 7" round duct
5th. 3-1/4" x 10"duct
6th. 6" round duct
The use of flexible metal round duct should only
be used when no other duct fitting exists. Limit
use to short lengths and do not crush when
making corners.
Install a wall cap with damper or roof cap at the
exterior opening. Order the wall or roof cap and
any transition needed in advance.
Use 8" round metal ductwork only.
Removing the packaging
Remove the carton carefully. Wear gloves to protect
against sharp edges.
WARNING
Remove the protective !lm covering the product
before putting into operation.