Atlantic Ultraviolet AeroLogic AERO-20 Manuel du propriétaire - Page 12

Parcourez en ligne ou téléchargez le pdf Manuel du propriétaire pour {nom_de_la_catégorie} Atlantic Ultraviolet AeroLogic AERO-20. Atlantic Ultraviolet AeroLogic AERO-20 16 pages.

Atlantic Ultraviolet AeroLogic AERO-20 Manuel du propriétaire
P
RECAUTIONS
®
The AeroLogic
who works in and around the system should be briefed on the precautions to be observed.
The HVAC system should be re-inspected for any ultraviolet light leakage whenever any maintenance or
modifications are performed.
If there are any doubts or concerns about the safety or the effectiveness of the installation, or if a sensitive
ultraviolet meter is required, please contact our application specialists.

MAINTENANCE

®
The AeroLogic
A regular cleaning cycle of the germicidal lamp and sight glass should be established, and carefully maintained,
based on inspection and experience. The frequency of cleaning will vary with the conditions surrounding each
installation. It is recommended that the ultraviolet lamp(s) be cleaned at least once every three (3) months.
The germicidal ultraviolet lamp used in the AeroLogic
10,000 hours. Lamps may operate longer than their rated effective life, but the reduction in ultraviolet output will
make it impractical to use past the manufacturer's rated life. For maximum efficiency lamp replacement is
recommended every 10,000 hours of operation or about one (1) year of continuous use.
Unless lamp replacement is due to failure or breakage, it is recommended that all lamps be replaced at the same time.
For proper germicidal lamp and/or quartz sleeve replacement and cleaning procedure see "Lamp Installation,
Replacement Or Cleaning" on page 11.
!
WARNING:
B
REAKAGE
!
CAUTION:
Wear protective gloves when handling broken ultraviolet lamps or quartz sleeves.
In the event of breakage, DO NOT use a household vacuum cleaner to pick up quartz fragments.
Sweep up debris into a plastic bag and dispose of properly.
D
M
ISPOSAL OF
Germicidal ultraviolet lamps, like standard fluorescent lamps contain small amounts of mercury. Mercury
added lamps should not be placed in the trash. Dispose of properly.
For further information regarding the disposal and recycling of lamps containing mercury, along with
Federal and State requirements visit http://www.lamprecycle.org. Product Data Sheets for germicidal
ultraviolet lamps can be found in the "PDF Library for STER-L-RAY
of http://www.ultraviolet.com.

OPTIONAL ACCESSORIES

1.
The Zenith
TM
Ultraviolet Meter is a sensitive, hand-held, ultraviolet meter that can be used to:
• Survey installations to ensure that the germicidal ultraviolet radiant exposure, of personnel within the treated
area, is within acceptable limits. The Zenith
intensity that may be interpreted by anyone - not just engineers.
• Check the intensity of aging ultraviolet lamps
The Zenith
TM
2. Observation Port Sight Glass Assembly - Additional
A Sight Glass Assembly allows for visual inspection of the lamp, without the need to remove the unit from the duct.
1 - 1 inch Sight Glass Assembly is included with each unit. If needed, additional Sight Glass Assemblies are
available in 1 and 2 inch diameters.
12
must be disconnected from power whenever anyone works on the HVAC system. Anyone
is designed to operate with a minimal amount of maintenance.
Always disconnect power to the unit before performing any service or maintenance.
Broken Quartz is SHARP.
A
L
ERCURY
DDED
AMPS
Part No. 30-0081-R is the recommended meter for this application.
®
have a manufacturer's rated average effective life of
®
Germicidal Ultraviolet Lamps" section
TM
Ultraviolet Meter provides accurate and easy-to-read levels of