Electrolux ZHT 910 Manuel d'installation, d'utilisation et d'entretien - Page 6
Parcourez en ligne ou téléchargez le pdf Manuel d'installation, d'utilisation et d'entretien pour {nom_de_la_catégorie} Electrolux ZHT 910. Electrolux ZHT 910 10 pages.
3.2 – Wall unit installation
Using the cardboard template, mark
and drill the bottom of the wall unit,
(see instructions on the template).
Fasten the hood from inside the unit
using four screws 4,2 x 44,4
(supplied) (fig.7). For suction hoods,
the wall unit must be drilled to allow
for the air discharge duct. Filter hoods
do not require this type of drilling
operation since the air is recycled into
the room through vents situated on
the front of the hood.
3.3 - Connecting suction or filter hoods
1 - Connecting suction hoods (air is discharged into the atmosphere)
The hood comes with two air outlets, a plastic cover
fitted in the rear hole and a flange to be fitted
according to the solution chosen: top discharge (fig.
8), rear discharge (fig. 9). In case of installation with
rear discharge, fit the plastic cover in the top hole
and the flange in the rear hole. Using a pipe Ø 100
o 120 mm, connect the air discharge flange to the
external discharge duct. Open the grid panel by
pressing inwards on the knobs (fig. 10), check that
the lever (hood with one motor) or the handle (hood
with two motors) points to the ducting mode position
(fig. 11), remove the charcoal filter, if any, by turning
the handle anti-clockwise (see par.3.3 2 part 2°).
Respect warning 2.1
1 0
1 0
1 0
Part 1 - INSTALLATION INSTRUCTIONS
8 8
8
9 9
9
7 7
7
13