MAINTENANCE
REPLACING & CLEANING
THE MAIN HEPA FILTER
The HEPA filter should be inspected every
two months, and cleaned when visibly dirty,
or replaced if damaged. This will help ensure
the best possible performance from your Volta.
1. Remove the dust container from the vacuum
cleaner and pull on the tab to remove the filter.
Note there is a sponge protection filter in front
of the HEPA filter, pull this filter away from the
HEPA filter frame.
2. Cover the HEPA filter with a sheet of paper
with the frame facing up and tap it against
a hard surface. This will help to dislodge
excessive dust and dirt from the filter.
3. If necessary, the HEPA filter can be rinsed under
a tap using lukewarm water. Always rinse the
filter with the frame facing down and never
use cleaning chemicals. Never scrub or brush
the filter. Rinse the sponge protection filter
under tap water.
4. Air-dry both the HEPA and sponge protection
filters for 24 hours, away from direct sunlight
before reusing it. If the filter appears damaged
it is recommended to replace with a new filter.
REPLACING & CLEANING
THE MICRO-EXHAUST FILTER
The micro-exhaust filter should be inspected
twice a year, and cleaned when visibly dirty,
or replaced if damaged.
1. To remove the micro-exhaust filter,
remove the exhaust grill, and lift the
filter frame out of the cleaner.
2. Like the HEPA filter, the micro-exhaust
filter can be rinsed under tap water.
Be sure to let it dry completely before use.
If the filter is damaged discard it and replace
with a new one.