Atlas Copco 8432084561 Instructions relatives au produit - Page 11

Parcourez en ligne ou téléchargez le pdf Instructions relatives au produit pour {nom_de_la_catégorie} Atlas Copco 8432084561. Atlas Copco 8432084561 16 pages. Handheld transducerized

Atlas Copco 8432084561 Instructions relatives au produit
ETD MT41-100-I06

Start options

The start mode of the tool can be configured as below:
Trigger start (default)
Press the start lever briefly.
Push start
Push the bit towards the screw and work piece.
Trigger and push start
Press the start lever and push the bit towards the screw and work piece.
For Trigger start and Push start, the tightening modes can be configured as below:
Hold (default)
The trigger must be pressed during the whole tightening process.
Pulse
The tool will fulfill tightening with just a start.

Function button

By default, the function button is configured with toggle reverse function to single push. That is, by pushing
the function button once, the reverse function is on.
The following user interaction types can be configured for function button:
single push
double-push
pressed
The following functions can be configured to each user interaction type:
Toggle reverse function
Single reverse function
Vacuum toggle
Guiding light toggle
Acknowledge for error codes
Integration with Digital I/O

Front light

By default, the front light is only configured to show a faulty tightening. That is, the light turns red when
there is a faulty tightening.
The intensity of the light and other functions can be configured in Tools Talk MT.
Status indicator
The front light can be configured to indicate status in Tools Talk MT:
Function
Tightening OK
Tightening NOK
Batch finished
EN
Color option
Green
Red
Green (default) or blue
© Atlas Copco Industrial Technique AB - 9839 1064 01
Run the tool in CCW.
Run the tool in CCW once and shift back in CW when
tightening is ready.
Start and stop Vacuum. Auto off after complete tight-
ening.
Start and stop Guiding light. Auto off after complete
tightening.
Acknowledge error codes from the tool instead of from
the controller's monitor.
Choose other functions from Digital I/O.
Default
Off
On
Off
Operation