Atlas Copco PHE50H Instructions de réparation - Page 15
Parcourez en ligne ou téléchargez le pdf Instructions de réparation pour {nom_de_la_catégorie} Atlas Copco PHE50H. Atlas Copco PHE50H 15 pages.

1
Mounting the
Push the plastic housing (A) over the ma-
auxiliary handle
chine.
2
Fit the cover (C).
3
Insert the dust seal (6) into the front of the
plastic housing (A).
4
Mount the tightening strap (B), the
screw (7), cover (8), support (5),
depth gauge (9) and clamping ring (4).
5
Insert the fan-type lock washer (1) into the
auxiliary handle (3) and fasten it with the
screw (2).
1
Mounting the
Mount the complete handle (5) on the
housing
plastic housing (3) and fasten it with
screws (4) and (6) as well as distance
sleeves.
2
Fit the motor cap (2) and fasten it with the
secured screws (1).
Test Run
Test run the machine and pay attention to noises.
Let the machine run-in.
Electrical Test
Perform an electrical test on the machine (see chapter Electrical and Mechanical Test Instructions).