Dromone Multi-Lock Quick Coupler Manuel du propriétaire - Page 12
Parcourez en ligne ou téléchargez le pdf Manuel du propriétaire pour {nom_de_la_catégorie} Dromone Multi-Lock Quick Coupler. Dromone Multi-Lock Quick Coupler 18 pages. Excavator automatic quick coupler
Bucket/Attachment Release
Before attempting the release of a
bucket or any other attachment it is im-
portant to check for the following.
A.
Ensure that the area within the
maximum machine swing radius
is clear of all personnel and
obstacles.
B.
Put attachment on level ground
to ensure that it does not roll
over.
Procedure:
1.Lower the 'Quick Coupler and attach-
ment to the ground with the 'Quick Cou-
pler' rotated fully inwards towards the
machine in order to disengage the auto-
matic latching system.
200mm
Fig 11. Lowering the bucket
2. Press the 'POWER' button on the in-
cab control panel to the, The visual Led
will pulsate GREEN and activate an audi-
ble buzzer (continuous tone) in the ma-
Figure 12
chine cab (
NOTE: If no further action is taken
within 5 seconds the unit will
automatically 'LOCK OUT', the
indicators will go out and the green
QMS 22
REV: D - JAN2012
Dromone Multi– Lock Quick Coupler
Ground
).
Dromone Multi– Lock Quick Coupler
LED light will return to a constant
green light.
Fig 12. Switching control box on
3. Activation of cylinders:
Press the 'CONTROL' button within 5 sec-
onds from switch on. The status indicator
light will illuminate to a flashing red sig-
nal and the buzzer will also change from
a continuous tone to a pulsating tone.
This indicates that a positive supply is
being sent to the solenoid valve, which in
turn operates the both lock cylinder.
Fig 13. Press 'CONTROL' Button
NOTE: After 'CONTROL' button is
pressed, the system will activate a
warning signal at 55 seconds, and
after 60 seconds the hitch will reset
to a closed position.
12
Author:EOD
Approved:MS