DROPSA 3414017 Manuel d'utilisation et d'entretien - Page 7
Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation et d'entretien pour {nom_de_la_catégorie} DROPSA 3414017. DROPSA 3414017 9 pages. Hydraulically controlled pump
9.2. SCHEDULED MAINTENANCE
The following table lists the periodic inspections, the frequency and the intervention that the maintenance will have to carry
out in order to ensure the efficiency of the system over time.
CHECK
Attachment of the lines.
Reservoir level.
Clogging of the filling filter.
Clogging of the return filter (where applicable).
Presence of deposits on the bottom of the
reservoir.
10. DISPOSAL
Do not dispose of polluting components in the environment during pump maintenance or in case of demolition; refer to local
regulations for correct disposal. Upon demolition of the pump, the identification label and any other document must be
destroyed.
11. ORDER INFORMATION
Part number
Command
3414008
3414012
Single acting
3414050
3414022
3414014
Dual acting
Part number
Command
3414004
Single acting
3414009
3414007
Dual acting
3414017
Voltage and
Part number
frequency
0044307
110V/50Hz
0044450
220V/50Hz
0044306
24V/50Hz
0044310
110V/50Hz
0044311
220V/50Hz
0044309
24V/50Hz
FREQUENCY
INTERVAL
After the first 500
hours of operation
Every 1500 hours of
operation.
As required.
400 work cycles.
400 work cycles.
600 work cycles.
Version WITH RESERVOIR for GREASE
Grease
Characteristics
NLGI 2
With grease-pusher disc and spring (2kg reservoir).
NLGI 1
With grease-pusher disc and MIN level electrical contact.
NLGI 2
With grease-pusher disc and MIN level electrical contact.
NLGI 2
With grease-pusher disc and spring.
NLGI 1
With grease-pusher disc.
Version WITHOUT RESERVOIR for OIL
Characteristics
Special reservoir applications.
For pumps P/N: 3414008; 3414012; 3414022; 3414050.
Special reservoir applications.
For dual acting pumps P/N: 3414014.
OPTIONAL KITS and ACCESSORIES
Characteristics
4-way solenoid valve for pumps P/N: 3414004; 3414008; 3414012; 3414022; 3414050.
4-way solenoid valve for pumps P/N: 3414007; 3414014.
INTERVENTION
Check the joint fittings.
Check the fastening to the parts of the machine.
Fill the reservoir with clean lubricant;
Disassemble and clean the filter.
Disassemble and clean the filter.
Clean the reservoir.
7