Daikin BRC7F532F Manuel de l'opérateur - Page 9

Parcourez en ligne ou téléchargez le pdf Manuel de l'opérateur pour {nom_de_la_catégorie} Daikin BRC7F532F. Daikin BRC7F532F 12 pages. Wireless remote controller kit

Daikin BRC7F532F Manuel de l'opérateur
How
to
designate
controller
Operate in the following order.
1
Continuously
press
SELECTOR button for 4 seconds.
The displays showing "
connected to the same outdoor unit or BS unit flash.
2
Press the OPERATION MODE SELECTOR button to
the indoor unit that you wish to designate as the
master remote controller. Then designation is
completed. This indoor unit is designated as the
master the remote controller and the display showing
"
" vanishes.
To change settings, repeat steps 1 and 2.

Emergency operation

When the remote controller does not work due to battery
failure or the absence thereof, use the switch which is
located beside the discharge grille on the indoor unit.
When the remote controller does not work, but the
battery low indicator on the remote controller is not lit,
contact your dealer.
1
START
To press the emergency operation switch.
The machine runs in the previous mode.
The system operates with the previously set air
flow direction.
2
STOP
Press the emergency operation switch again.
BRC7F532+533F
Wireless remote controller kit
the
master
remote
the
OPERATION
MODE
" of all slave indoor units
1•2
4PW29216-1
Precautions for group control system or two
remote control system
This system provides two other control systems beside
individual control (one remote controller controls one
indoor unit) system. Confirm the following if your unit is of
the following control system type:
Group control system
One remote controller controls up to 16 indoor units.
All indoor units are equally set.
Two remote controller control system
Two remote controllers control one indoor unit. (In
case of group control system, one group of indoor
units.)
The unit follows individual operation.
NOTE
Cannot have a two remote controller
control system with only wireless
remote controllers. (It will be a two
remote controller control system having
one wired remote controller and one
wireless remote controller.)
Under two remote controller control
system, wireless remote controller
cannot control timer operation.
Only the operating indicator lamp out of
3 other lamps on the indoor unit display
functions
Contact your dealer in case of changing the
combination or setting of group control and
two remote controller control systems.
H
OW TO DIAGNOSE TROUBLE SPOTS

Emergency stop

(See figure 2)
When the air conditioner stops in emergency, the
operation lamp on the indoor unit starts blinking.
Take the following steps yourself to read the malfunction
code that appears on the display. Contact your dealer
with this code. It will help pinpoint the cause of the
trouble and speeding up the repair.
1
Press the INSPECTION/TEST button to select the
inspection mode " "
" " appears on the display and blinks. "UNIT" lights
up.
2
Press PROGRAMMING TIMER button and change
the unit number.
Press to change the unit number until the indoor unit
beeps and perform the following operation according
to the number of beeps:
Number of beeps
- 3 short beeps.......... perform all steps from 3 to 6
- 1 short beep .....................perform 3 and 6 steps
- 1 long beep......................................normal state
Operation manual