6.4 ELECTRIC CONNECTIONS
Connect the unit to the pump or to the pressurized reservoir using suitable piping for the working pressure that must not be
greater than 2.5 times the air pressure (es.: air 6bar [87psi] – oil 15bar [217,5psi] max.).
6.5 AIR/OIL HYDRAULIC CONNECTIONS TO THE LUBRICATION NOZZLE
Using coaxial pipes, connect the Ø3mm pipe
Ø3mm tube until connect it to the air outlet push-in
Then connect the same coaxial pipes to the lubrication nozzle push-in as shown below:
1. Insert the Ø6 air pipe in the push-in on the nozzle connection.
2. Remove the nozzle head from the articulated pipe, through which the Ø3 oil tube should pass, making it protrude approx.
20/25mm.
3. Insert the Ø3 oil pipe in the push-in on the nozzle head.
4. Replace the nozzle head on the articulated pipe.
To make it easier to remove the pipes exiting the module, use the supplied device: unscrew the Ø6 push-in, insert the device in
the Ø3 pipe, push the device on the collar of the Ø3 push-in, push and pull the Ø3 pipe.
to the oil outlet push-in
2
OIL
AIR
on the module, slide the Ø6mm tube
.
4
3
1
AIR
OIL
AIR
outside the
6