Anleaf Technologies AP300W Manuel de l'utilisateur - Page 6

Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Anleaf Technologies AP300W. Anleaf Technologies AP300W 7 pages. Portable solar power generator

2.1. High Power Storage Battery
If the LED indicates green light, the power of battery shows in full level and the voltage is above 12.6V
usually.
2.2. Low Power Storage Battery
If the LED indicates yellow light, the battery power shows in low level, then user can choose the DC
output; the battery could be used for some time.
2.3. Protection for Low Voltage
If the red LED light is flashing, the Under-Voltage-Protection (UVP) will be working at once. When the
UVP is working, the protection system will reject any operation and auto checks up the status of battery
storage. At this stage, if the voltage is under 9.6V, the LED display will auto shut off.
3. Discharging:
The most output is 360W including AC/DC discharging at the same time. If the
turned on, the device will be ready for operation; user should pay attention to the status of battery power.
3.1. AC Discharge (300W/600VA)
In using AC output, please turn on the AC power switch. User should care about the input ratings of load
& also check what the voltage is (110VAC or 220VAC). Note: 5VDC USB socket is set up at this unit
with a rating of 5VDC/500m A.
3.2. DC Discharge (Constant DC output socket & Car cigarette output socket is 12VDC/6A)
In using DC output, please turn on the DC power switch. User should care about the input ratings of load
& check if the DC rating is less than the power consumption. Please refer to the DC outlet rating as
specification.
Trouble Shooting:
1. If AC load cannot keep working, please check up the solar power bank according to the following
procedures:
1.1. Please check if the rated power of the load is <300W ?
1.2. If the rate is the same as <300W condition, please check whether the voltage of battery storage has
got a "Duty Cycle". Usually High Electric Potential will drive the AC load, but if an AC load gets higher
wattage, it will absorb higher current draw and also work continually, the UVP will be started to protect the
system and auto shut down. In this case, please check whether DC outlet is working normally, if so, please
re-charge the battery.
1.3. If the LED display of battery storage shows the status of full or normal power however the AC output
cannot work, the UVP will be started due to the single cell volt may be dropped to 2.4V.
If the single cell gets such problem, it could be aging, we suggest that you should change into new battery
or send it back for investigation.