Drummond MTL10 Mk3 Manuel d'instruction - Page 5

Parcourez en ligne ou téléchargez le pdf Manuel d'instruction pour {nom_de_la_catégorie} Drummond MTL10 Mk3. Drummond MTL10 Mk3 20 pages.

damage to the cable to be easily identified. If there is any doubt the
voltage indicator should not be used.
Make sure the voltage indicator is dry, clean and free from dust,
grease and moisture while in use to avoid the danger from electric
shock due to surface leakage.
Before and after each use, the voltage indicator must be proven
using a suitable proving device or a known good voltage source. Do
not use the voltage indicator if any expected LED's fail to illuminate
correctly during proving.
Testing for a voltage that exceeds the specified limits of the voltage
indicator may damage the voltage indicator and may expose the
operator to a shock hazard. Always check the voltage indicator's
specified limits before use.
The specified measurement category means the voltage indicator
will be safe to the user if connected to a voltage up to 1000V to
earth on a CAT II, CAT III or CAT IV installation for MTL15. For
MTL10, 1000V to earth on a CAT II or CAT III installation and 600V
to earth on a CAT IV installation. It does not mean it can be used to
test for a voltage beyond its maximum working voltage.
If using the voltage indicator in damp conditions, the operator must
use additional protection to avoid the danger from electric shock
due to surface leakage.
Select appropriate test prods and secure with captive ring nuts. The
L-shaped test prods should be oriented in one of four directions
using the square location feature before it is secured.
When changing or adjusting the prods, ensure that both prods have
been disconnected from any source of power or other equipment.
Always keep your fingers behind the finger guards. Never touch the
exposed metal prod tips.
3