Operation Handbook
Button Locations and Descriptions
MODEL: BRC1H61W/BRC1H61K
LCD
Status indicator (LED)
During operation, the light
ring around the display
lights up blue/red/green.
Lights up blue: Operating,
Blinks red: Error is occurring,
Lights up/blinks green:
Bluetooth connecting
NAVIGATE/ADJUST button
SELECT/ACTIVATE/SET button
Navigate left.
From the home screen, enter the main menu.
Adjust a setting.
From the main menu, enter one of the submenus.
From their respective submenu, activate an operation/ventilation mode.
Read this manual before using the product.
• This manual describes the basic operation of the indoor unit which uses the BRC1H61W/BRC1H61K
remote controller. Keep this manual where it is readily accessible, and refer to it when necessary.
• For detailed contents, refer to the BRC1H61W/BRC1H61K operation manual on our website.
Also, for explanation about things other than remote controller operation, refer to the operation
manual attached to the indoor unit.
Safety Precautions
Also refer to installation manual attached to the indoor unit.
Please read these "Safety Precautions" carefully before installing the remote controller.
• This manual classifies the precautions into WARNINGS and CAUTIONS.
Be sure to follow all the precautions below: They are all important for ensuring safety.
Indicates a potentially hazardous situation which, if not avoided, could
WARNING
result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided, may
CAUTION
result in minor or moderate injury.
It may also be used to alert against unsafe practices.
• After completing installation, conduct a test operation to check for faults and explain to the customer
how to operate the remote controller and cleaning of it with the aid of the operation manual. Ask the
customer to store the installation manual along with the operation manual for future reference.
Ask your dealer or qualified personnel to carry out installation work.
Do not attempt to install the remote controller yourself.
Improper installation may result in electric shocks or a fire.
Consult your local dealer regarding relocation and reinstallation of the remote controller.
Improper installation may result in electric shocks or a fire.
Install the remote controller in accordance with the instructions in this installation manual.
Improper installation may result in electric shocks or a fire.
Be sure to use only the specified accessories and parts for installation work.
Failure to use the specified parts may result in the remote controller falling down, electric shocks or a
fire.
Install the remote controller on a foundation that can withstand its mass.
Insufficient strength may result in the remote controller falling down and causing injury.
Make certain that all electrical work is carried out by qualified personnel according to the applicable
legislation (note 1) and this installation manual, using a separate circuit.
In addition, even if the wiring is short, make sure to use a wiring that has sufficient length and never
connect additional wiring to make the length sufficient.
Insufficient capacity of the power supply circuit or improper electrical construction may lead to
electric shocks or a fire.
(note 1) applicable legislation means "All international, national and local directives, laws, regulations
and/or codes which are relevant and applicable for a certain product or domain".
Turn off the power before performing installation work.
Touching live parts may cause electric shocks.
Do not disassembly, reconstruct or repair.
Failure to do so many cause electric shock or a fire.
Make sure that all wiring is secured, using the specified wirings and ensuring that external forces do
not act on the terminal connections or wirings.
Improper connections or fixing may cause an overheat or a fire.
The choice of materials and installations must comply with the applicable national and international
standards.
ON/OFF button
Press this button to turn
on the system.
Press this button again to
turn off the system.
NAVIGATE/ADJUST button
Navigate right.
Adjust a setting.
WARNING
3P607381-2
Information screen
EM19A037
English
The current status is displayed with icons.
About icons on the information screen
The items displayed vary depending on the indoor unit you are using.
Icon
Information
MAIN/SUB remote
controller
Bluetooth*
Clock not set
Setback
Centralized Control
Changeover Under
Control (VRV only)
Backup
Energy savings
Individual airflow
direction
Test operation
Defrost/Hot start
Self-cleaning filter
operation
Inspection
Periodic inspection
Ventilating operation Indicates that ventilating operation is being carried out.
Warning
* The Bluetooth® word mark and logos are registered trademarks owned by the Bluetooth SIG, Inc. and
use of such marks by Daikin industries, LTD. is under license. Other trademarks and trade names are
those of their respective owners.
To avoid electric shocks due to entry of water or insects, fill the wiring through hole with putty.
Do not operate with wet hands to avoid electric shocks.
Do not wash the remote controller with water.
Failure to do so many cause electric shock or a fire.
Install the air conditioner, power supply wiring, remote controller wiring and transmission wiring at
least 1 meter away from televisions or radios to prevent image interference or noise.
(Depending on the radio waves, a distance of 1 meter may not be sufficient to eliminate the noise.)
Do not install the remote controller in the following locations:
1. Where there is oil mist, oil spray or vapour for example a kitchen.
Resin parts may deteriorate and fall off.
2. Where corrosive gas, such as sulphurous acid gas, is produced.
3. Where there is machinery which emits electromagnetic waves.
Electromagnetic waves may disturb the control system, and cause a malfunction of the
equipment.
4. Where flammable gas may leak, where there is carbon fibre or ignitable dust suspensions in
the air, or where volatile flammables such as thinner or gasoline are handled.
Operating the unit in such conditions may result in a fire.
5. High temperature area or near a heat source.
It may cause an overheat or a fire.
6. Moist area, or place where may be exposed to water.
If water enters inside of the remote controller, electrical components may fail.
It may result in electric shocks or a fire.
When remote controller's thermostat sensor is used, select the installation location by considering
the followings.
• A place where average temperature in the room can be detected.
• A place where is not exposed to direct sunlight.
• A place where is far apart from heat source.
• A place where is not affected by outdoor air due to door opening/closing or the like.
Maintenance
Maintaining the Unit and LCD Display
• Wipe the LCD and surface of the remote controller with a dry cloth when they become dirty.
• If the dirt on the surface cannot be removed, soak the cloth in neutral detergent diluted with
water, squeeze the cloth tightly, and clean the surface. Wipe the surface with a dry cloth.
• Do not use non-neutral detergents or organic solvents (alcohol disinfectant, benzene,
paint thinner, etc.).
May cause cracking, electric shocks or fire.
NOTICE
Do not use any paint thinner, organic solvent, or strong acid.
Name
Description
Indicates an information screen.
Displayed when used as the MAIN/SUB remote controller.
1=main, 2=sub
Indicates that the controller is communicating with a
mobile device, for use with the app.
Indicates that the clock needs to be set again.
Indicates that the indoor unit is operating under setback
conditions.
Indicates that the system is controlled by central control
equipment (optional accessory) and that control of the
system by the controller is limited.
Displayed:
The remote controller does not have master control.
Unable to select heating/cooling operation.
Blinking:
None of the remote controllers in the system have master control.
Can be set as the master controller during this time.
Not Displayed:
The remote controller has master control.
Able to select heating/cooling operation.
Indicates that backup operation is being carried out.
Indicates that the system's energy consumption is being
limited, and that it is running with restricted capacity.
Indicates that the individual airflow direction setting is
enabled.
Indicates that Test Operation mode is active.
Indicates that the defrost/hot start mode is active.
Indicates that selfcleaning filter operation is active.
Indicates that the indoor or outdoor unit is being
inspected.
Indicates that the indoor or outdoor unit is being
inspected.
Indicates that an error occurred, or that an indoor unit
component needs to be maintained.
CAUTION