3. Installation

3.1 Mounting the fixture

The ArcLine DVP Integral can be arranged in any orientation on a flat, non-flammable surface by means of the wall
mount adaptor .
1. Screw both mounting brackets (2) on a flat surface by means of suitable flat-head screws (3). The hole in the
mounting bracket (2) has a diameter of 6.2mm.
2. Place the ArcLine DVP Integral (1) into the mounting brackets (2) and secure the unit by means of the two
holders (4) with two screws M5x12 (5) each.
Ensure that the structure to which you are attaching
the unit is secure.

3.2 Connecting to mains

The unit must be installed by a qualified electrician in accordance with all national
and local electrical and construction codes and regulations.
This device falls under class one and must be grounded!
The ArcLine DVP Integral is equipped with auto-switching power supply that automatically adjusts to any 50-60Hz
AC power source from 100-277 Volts.
A 5-cored cable Flamar Li9YC11Y with 12-pin conector Chogori serves for data/power input. Three cores serve for
the power supply and next 2 shielded cores are intended for DMX connection as shown in the table.
Core
Connection
Core
Connection
Black
Live
Red
Data +
Blue
Neutral
White
Data -
Yellow/Green
Shielding
0
The ArcLine DVP module should be connected to the Data Configurator unit which allows power supply of the
ArcLine DVP modules and their addressing and setting. Please see the user manual of the Data Configurator.