Care and Cleaning
■ ■ ■ ■ Replacing the Titanium apatite
photocatalytic filter roll
Replace the Titanium apatite photocatalytic filter roll when the "Replace
indicator" (Page 4) is lit or flashes in the main unit display.
Target is once every year.
CAUTION
• The unit must be operated with a pre-filter and Titanium apatite
photocatalytic filter roll set.
If they are not set and the unit is operated, malfunctions may occur.
• Do not strongly press on the photocatalyst.
The special inverter lamp located inside may be cracked.
• Do not remove the photocatalyst.
• Do not wash the photocatalyst in water.
NOTE
• The replacement period differs depending on the use method
and installation location.
• The replacement period will shorten if the unit is used where
the air is dirty.
1. Stop the operation and unplug the power plug from the
electrical outlet.
2. Remove the front panel.
• Refer to procedure 1 on Page 8.
3. Remove the plasma ionizer.
• Hold the handle and pull the ionizer toward you raising it up.
4. Remove the old Titanium apatite photocatalytic filter roll.
5. Take the Titanium apatite photocatalytic filter roll out from
the Titanium apatite photocatalytic filter roll receiver.
6. Cut off one piece of the Titanium apatite photocatalytic
filter roll along the perforation.
Hole
Hole
7. Install the Titanium apatite photocatalytic filter roll.
• List up the dark colors of the surface and then correctly insert into
the hooks (four) of the plasma ionizer.
Hole
Hook
9
/ English
Handle
Titanium apatite
photocatalytic filter roll
Titanium apatite
Hole
photocatalytic
filter roll
Dark colored
surface
Hook (4 locations)
CAUTION
If the front surface and rear surface of the filer are mis-
taken, the performance will drop.
• Store the remaining Titanium
apatite photocatalytic filter roll in
the Titanium apatite photocata-
lytic filter roll receiver.
NOTE
The Titanium apatite photocatalytic filter roll can also be set without
being cut. (Page 6)
For this case, you can also replace the filer as shown below.
(1) Remove the Titanium apatite
photocatalytic filter roll from
the hooks (four) and pull it
out. Then correctly insert
into the next Titanium apatite
photocatalytic filter roll into
the hooks (four).
(2) Cut along the perforation
8. Install the plasma ionizer in its original configuration.
9. Install the front panel to its original position.
• Refer to procedure 5 on Page 8.
10. Insert the power plug into the electrical outlet.
11. Press the reset button of the main unit display.
Press using a thin pointed
object to cancel the filter
replace sign.
(A beeping sound will be
heard.)
■ ■ ■ ■ Cleaning the plasma ionizer
Clean when the "Clean indicator" (Page 4) flashes in the main unit
display.
1. Stop the operation and unplug the power plug from the
electrical outlet
2. Remove the front panel.
Refer to procedure 1 on Page 8.
3. Remove the plasma ionizer.
Refer to procedure 3 on Page 9.
Hook (4 locations)