Daikin Altherma 3 R F Manuel d'utilisation - Page 7

Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation pour {nom_de_la_catégorie} Daikin Altherma 3 R F. Daikin Altherma 3 R F 12 pages.
Également pour Daikin Altherma 3 R F : Manuel de référence de l'utilisateur (20 pages), Manuel d'utilisation (16 pages), Manuel d'utilisation (16 pages), Manuel d'installation (12 pages)

Daikin Altherma 3 R F Manuel d'utilisation
T t
1
2
60°C
50°C
40°C
15°C
00:00
07:00
T
Domestic hot water tank temperature
t
t
Time
3.4.3

Scheduled + reheat mode

In scheduled + reheat mode (   ), the domestic hot water control is
the same as in scheduled mode. However, when the DHW  tank
temperature drops below a preset value (=reheat tank temperature –
hysteresis value; example: 35°C), the DHW  tank heats up until it
reaches the reheat set point (example: 45°C). This ensures that a
minimum amount of hot water is available at all times.
Example:
T t
1
2
60°C
50°C
45°C
35°C
15°C
00:00
07:00
T
Domestic hot water tank temperature
t
t
Time
3.4.4
Using the DHW tank temperature home
page
Typical DHW tank temperature home pages
Depending on the user profile, the user interface gives you either a
basic or a detailed home page. The examples in the illustrations
below are in DHW tank mode = Scheduled.
User profile = Basic
Mon
15:20
Tank
60°C
Storage comfort
To read out and adjust the desired reheat temperature (in
scheduled and reheat mode)
1 Go to [7.4.3.3]:
> User settings > Preset values > Tank
temperature > Reheat.
Result: You can read out the desired reheat temperature.
2 Press
or
to adjust.
To read out and overrule the active or next scheduled desired
temperature (in scheduled mode or scheduled + reheat mode)
1 Go to the DHW tank temperature home page (Tank).
60°C
Result:
is displayed.
2 Press
or
to overrule.
Note: If the desired temperature is weather dependent, you cannot
change it on the home page.
EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596819-1 – 2019.10
4
3
5
t
14:00
21:00
3
4
5
t
14:00
21:00
User profile = Detailed
Mon
15:20
60°C
Tank
Storage comfort
Tue
00:00
3.4.5
Using the DHW tank booster mode
To activate the DHW tank booster mode (user profile = Basic)
1 Go to the DHW tank temperature home page (Tank).
2 Press
for more than 5 seconds.
To activate the DHW tank booster mode (user profile = Detailed)
1 Go to the DHW tank temperature home page (Tank).
2 Press
to select .
3.5

Schedules: Example

INFORMATION
The procedures to program other schedules are similar.
In this example:
▪ Monday = Tuesday = Wednesday = Thursday = Friday
▪ Saturday = Sunday
To program the schedule
1 Select Empty and press
2 Program the schedule for Monday. See below for more details.
3 Copy from Monday to Tuesday, Wednesday, Thursday and
Friday. See below for more details.
4 Program the schedule for Saturday.
5 Copy from Saturday to Sunday.
6 Save the schedule and give it a name. See below for more
details.
To program the schedule for Monday
1 Use
and
to select Monday.
2 Press
to enter the schedule for Monday.
3 Program the schedule for Monday:
▪ Use
and
to select an entry.
▪ Use
and
to change the value of an entry.
To copy from one day to another
1 Select the day from which you want to copy and press
Example: Monday.
2 Select Copy day and press
3 Set the days you want to copy to Yes and press
Tuesday = Yes, Wednesday = Yes, Thursday = Yes and Friday
= Yes.
To save the schedule
, select Save schedule and press
1 Press
2 Change the name and press
temperature schedules). Example: MyWeekSchedule
To select which schedule you currently want to use
> Select schedules.
1 Go to [5]:
2 Select for which control you want to use a schedule. Example:
[5.1] Room temperature.
3 Select for which operation mode you want to use a schedule.
Example: [5.1.1] Heating .
4 Select a predefined or user‑defined schedule and press
3 Operation
.
.
. Example:
.
. (Only applicable for room
Operation manual
.
.
7