Dryton MiTime T720M Manuel du propriétaire - Page 2

Parcourez en ligne ou téléchargez le pdf Manuel du propriétaire pour {nom_de_la_catégorie} Dryton MiTime T720M. Dryton MiTime T720M 2 pages. Mitime programmer series rf packs

Step 4: Prog. Timetable
Step 5: Period Settings
Zone = Heating
Day range & period
Highlight shows adjustable field:
Link to Copy days
Use up/down buttons to adjust values
Timetable day range: Monday to
Period settings: On at 6:30am and Off
Friday (Week and weekend)
at 8:30am
Options: Individual days (7day), Week and
weekend (5/2day), All week (24hr). The
Help text: Use left/right buttons to
available blocks depend on the selection
change fields
in menu "change timetable type"
Help text: Use left/right buttons to
Stored programmes
select the days you want to change
MiTime contains 3 pre-set programmes. An
example is shown below. These programmes can
Arrow denotes that further options are
be modified according to personal needs and
available if you scroll down.
can be stored by using a name. Via this name they
also can be reloaded. Once a programme has
been modified, the original factory pre-set will no
Period 1 settings: describes the current timetable
longer be available. On a System Reset, only the
settings, e.g. Heating has been programmed to
current loaded programme will be replaced with
turn On at 6:30am and go off at 8:30am
the factory setting – see Installation Guide Step 4.
Period 2 settings: describes the current timetable
Programme 1
settings, e.g. Heating has been programmed to
Example:
turn On at 4:30pm and go off at 10:30pm
1st On
Press select ( ) when highlighted to adjust
1st Off
settings (see Step 5)
2nd On
Up to 4 periods can be programmed
2nd Off
Step 7: Keys and Display - MiStat
RF Pack: MiStat N110R, MiStat C110C
RF transmission indication.
Current room temperature
The RF symbol will be
visible as follows,
Short flashes indicates an
RF transmission.
Current Setting,
see table below
Long flashes indicates an RF
transmission issue.
key: Press to
toggle between
Comfort setting, Eco
setting and Home
(Room thermostat
only). See table below.
key: Press to
cancel +hr and display
home. (Cylinder
thermostat only)
Select key: Press
to open and save
editor screens
Symbol in
Function
Description
display
Selects the comfort setting. The pre-set value is used
Comfort setting
each time when activated, adjustable within the menu
Selects the Eco setting. The pre-set value is used each
Eco setting
time when activated, adjustable within the menu.
Indicates that the pre-set temperatures were changed
None
Home screen
via +/- key
6444 Invensys MiSeries RF Channel USER 06490193001 IssF.indd 2
Step 6: Additional User Settings
Feature:
Description:
Programme
On & Off times for the current period can be
Timetable
modified. See description in 'Step 4'
Copy days
Will copy the current day to one or more other days
Add Period
Adds a Time event. It will be added at the correct
position within the day. There is a maximum of 4
periods.
Remove Period
Removes the selected period. There needs to be at
least 1 period
Change
The visible day-blocks available in "programme
Timetable Type
timetable" can be defined, see Step 4
Individual days
Each day can be programmed individually
Week and
Mon... Fri and Sat... Sun can be programmed as 2
weekend
blocks
All week
Mon...Sun can be programmed as one block
Stored
MiTime contains 3 pre-set programmes. These
programmes
programmes can be modified according to personal
needs and can be stored by using a name. Via this
name they can also be re-loaded. Once a programme
has been modified, the original factory pre-set will no
longer be available unless a System Reset is applied -
see Installation Guide Step 4.
All week
Week & Weekend
Load stored
A pre-set programme can be loaded
programme
Mon-Sun Mon-Fri
Sat-Sun
Save current
The current programme can be saved by name (Each
6:30am
6:30am
7:00am
programme
pre-set program includes: Individual days, week/
8:30am
8:30am
9:00am
weekend, all day and custom day schedules)
4:30pm
4:30pm
4:00pm
10:30pm
10:30pm 11:00pm
Step 8: +hr (Boost)
Call for heat indication.
This flame will be visible
when the room
temperature is below
the set temperature.
Current set temperature
Press +hr to Boost
+hr key: Press to add up
to 3 hours to the current
period or to get instant
1 to 3 hours if currently
off (see step 8).
+ & - keys:
Press to change
the current
temperature or
turn the heat on
MiStat
if currently off
Press +/- to adjust +hr period between 0 and 3 hours
Press ( ) to confirm
Now the Boost is running. The time will be counted
Note: Settings
down each hour.
changes can be
made via the
Once the time has elapsed, control returns to the
MiTime unit
prior temperature screen.
The Boost can be cancelled by pressing the (
or by setting the +hr period to 0.
Feature:
Factory Pre-Set:
Help Tips
Holiday switch
off
Status
Zones
Holiday start
time (From)
Holiday start
Default
date (From)
Holiday end time
(To)
Programme 1
Holiday end date
(To)
Time and date settings
Set time
Set date
Daylight saving
Clock format
Step 9: Changing the Batteries
How do I know when to change
the batteries?
When the batteries start to run low a battery icon will
flash in the display to indicate "low battery", during
this time the MiStat will function normally. When the
battery icon alone is alone is shown in the display, the
batteries are completely exhausted and the MiStat will
cease to function (see below). Re-activate by replacing
the batteries.
MiStat
) key
Press Select to enter a specific
Setting. Options shown below:
Description:
Factory Pre-Set:
Describes the button functions
In the period until holiday starts the product will operate normally.If holiday
is disabled manually or terminates automatically, the mode before start
of holiday will be re-instated.An enabled holiday will be indicated with a
suitcase symbol in the top line. If holiday is active, in the Set: line the holiday
end date will be indicated. In the Summary screen the suitcase will be visible
together with the holiday temperature.
Enable or disable holiday mode.
Disabled
Holiday mode can be applied to a specific zone or
All zones
all zones
Set the time for the start of your holiday
Current time -
nearest hour
Set the date for the start of your holiday
Today
Set the time for the end of your holiday
Current time -
nearest hour
Set the date for the end of your holiday
Today + 1 week
To set time of day
Factory set
To set date
Factory set
To enable or disable daylight saving
Enabled
To select 12h or 24h clock mode
12hr
How to replace the batteries
Remove the battery covers as shown. Replace the batteries with 2 x 1.5V IEC LR6 (AA) Alkaline batteries ensuring
correct orientation. Replace the battery covers pressing fully home.
Mi Sta t
Troubleshooting:
1
Setting temperature values is restricted
Are Minimum/Maximum temperatures activated?
a
see Installation Guide Step 8.
NO SIGNAL is visible on the screen, no reaction on
2
key presses anymore
Is the receiver powered? (Red signal lamp should
a
be visible)
Is the room thermostat powered? see Homeowner
b
Guide Step 9.
3
LOCKED is displayed on the room themostat
a
see Installation Guide Step 8 - Screen Lock
4
Is the battery symbol visible?
a
Replace batteries, see Homeowner Guide Step 9.
STARTING is visible on the thermostat screen, no
5
reaction on key presses anymore
Is the receiver powered? (Red signal lamp should
a
be visible)
WAIT is visible on the thermostat screen, no reaction
6
on key presses anymore
Is the receiver powered? (Red signal lamp should
a
be visible)
MiStat Rear
Battery Covers:
Slide outwards
to remove
Battery Handling
Batteries, rechargeable or not, should not be disposed
of into ordinary household waste. Instead, they must be
recycled properly to protect the environment and cut down
the waste of precious resources.
Your local waste management authority can supply details
concerning the proper disposal of batteries.
In compliance with the EU Directive 2006/66/EC, the button
cell battery located on the printed circuit board inside the
product, can be removed at the end of the product life, by
professional personnel only.
27/09/2013 09:19