4. Horizontal Blades

Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
1
Bend the horizontal
blade (lower) slightly
and release the 2
center shafts.
2
Release the left shaft.
3
Slide the horizontal
blade (lower) to the left
and release the right
shaft.
4
Remove the horizontal
blade (upper) in the
same way.
Removal Procedure
All manuals and user guides at all-guides.com
Procedure
Center shaft
Left shaft
When reassembling, mount
the large horizontal blade to
the upper position and the
small horizontal blade to the
lower position.
Horizontal blade
(upper)
Horizontal blade
(lower)
(R21152)
Installation procedure
1. Fit the horizontal blade to the
right shaft first. Make sure to
rotate the horizontal blade so
the shaft fits correctly.
2. Fit the horizontal blade to the
center and left shafts.
Right shaft
(R2766)
Horizontal Blades